From fixed to SyncAV: evaluating the real-world effects on CRT patients
S Esteves, D Rosa Ferreira, D Cazeiro, M Vilela, J Cravo, B Andrade, J Brito, A Bernardes,
Key points
From the paper's conclusion- Conclusion Switching to the SyncAV algorithm in CRT patients previously on fixed AV delay led to additional QRS shortening.
Abstract
Introduction Optimizing atrioventricular (AV) timing is a key factor in maximizing cardiac resynchronization therapy (CRT) benefits. While initial AV programming may be fixed, individualized AV-synchronous pacing with the SyncAV algorithm could provide additional hemodynamic advantages. The long-term effects of switching from fixed AV delay to SyncAV remain unclear. Aim To compare clinical outcomes, echocardiographic and electrocardiographic changes of CRT patients initially programmed with fixed AV delay and subsequently switched to SyncAV. Methods This was a prospective follow-up trials that include patients with a CRT programmed with fixed AV delay for 12 months who underwent switch to SyncAV algorithm. Primary endpoints included the composite of all-cause mortality and hospitalizations. Secondary endpoints included changes in QRS and echocardiographic parameters. Results We included 62 patients (52.9% male), with a mean age of 68.9± 9.6 years. 72.9% of the patients had dilated cardiomyopathy and 78.6% were on functional class II of the NYHA. At baseline, the mean left ventricular ejection fraction (LVEF) was 48.5%, the mean intrinsic QRS was 157 ms and the median percentage of biventricular pacing (BIV) was 99%. The baseline heart failure medications and comorbidities are in Table 1. After 12 months follow up, the primary endpoint occurred in 13 patients. When comparing our patients with those who had CRT with SyncAV activated from device implantation, no differences in clinical events were observed, suggesting that the SyncAV algorithm is not associated with clinical benefit in CRT patients, regardless of the duration of algorithm activation- Graph 1. Considering the secondary endpoints, after 12 months of SyncAV activation, median intrinsic QRS duration was reduced by 7 ms relative to baseline values and median QRS duration in pacing was reduced by 14 ms. The SyncAV algorithm was associated with modest improvement in LVEF (+ 4.1%) and index left ventricular end systolic volume (1.1 mL/m2)- Table 2. Conclusion Switching to the SyncAV algorithm in CRT patients previously on fixed AV delay led to additional QRS shortening. However, this did not translate into significant left ventricular reverse remodelling nor clinical benefit at 1 year.Endpoints
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Role of Atrial Pacing Support in Cardiac Resynchronization Therapy: A Noninferiority Randomized TrialCirculation · 2026
- Predictors of left ventricular ejection fraction improvement following conduction system and biventricular resynchronization: a subanalysis of the PhysioSync-HF trialEuropean Heart Journal · 2026
- Cardiac Resynchronization TherapyJAMA · 2026
- Efficacy of Atrioventricular Node Ablation Versus Medical Rate Control for Enhancing CRT Response in Permanent Atrial Fibrillation: A Systematic Review and Meta-Analysis of Randomized Controlled TrialsCardiology in Review · 2026
- Left bundle branch area vs biventricular pacing for cardiac resynchronization therapy: the LEFT-BUNDLE-CRT trialEuropean Heart Journal · 2026
- Predicting Persistent Left Ventricular Dysfunction After Cardiac Resynchronization Therapy Upgrade in Pacing-Induced Cardiomyopathy.Journal of clinical medicine · 2026