When bundle branch blurs the signal: How accurate is electrocardiographic criteria for outflow tract premature ventricular complexes?
S Rose, R Jain, M Osment, S Gautam, K Akella
Key points
From the paper's conclusion- Background Published electrocardiographic (ECG) criteria for localizing outflow tract premature ventricular complexes (PVCs) lack validation regarding their diagnostic accuracy in the presence of bundle branch block (BBB).
Abstract
Background Published electrocardiographic (ECG) criteria for localizing outflow tract premature ventricular complexes (PVCs) lack validation regarding their diagnostic accuracy in the presence of bundle branch block (BBB). Purpose To evaluate the accuracy of commonly used ECG criteria for outflow tract PVC localization in the presence of BBB. Methods Data from the Ventricular Arrhythmia Catheter Ablation (VACA) registry were analyzed. Patients were included if continuous cardiac monitoring was available for >24 hours before and after ablation to quantify PVC burden. Procedural success was defined as a ≥75% reduction in PVC burden. Forty-two consecutive patients who underwent PVC ablation between January 2024 and October 2024 were identified; three patients were excluded due to <75% PVC reduction. A total of 61 distinct PVC morphologies were analyzed. Two ECG criteria for outflow tract PVC localization were evaluated:A precordial transition during PVC occurring later than sinus rhythm excludes a left ventricular outflow tract (LVOT) origin.A precordial R/S transition beyond lead V3 indicates a right ventricular outflow tract (RVOT) origin, whereas transition at or before V3 indicates an LVOT origin. Results Thirty-nine patients (27 male, 12 female; mean age 59 ± 15 years) met inclusion criteria, contributing 61 distinct PVC morphologies. All patients underwent transthoracic echocardiography (TTE), and 33 had pre-procedural cardiac magnetic resonance imaging (CMR). Sixteen patients had no structural heart disease, 10 had ischemic cardiomyopathy (ICM), 11 had non-ischemic cardiomyopathy (NICM), and 2 had mixed ischemic and non-ischemic cardiomyopathy. PVC origins included 13 from the left ventricular (LV) papillary muscles, 3 epicardial, 3 LV septal, 4 right ventricular (RV) septal, 1 parahisian, and 11 from other LV locations. Twenty-nine PVCs originated from the outflow tracts. BBB during sinus rhythm was present in 10 cases (7 right bundle branch block [RBBB], 3 left bundle branch block [LBBB]). In patients without BBB, the first criterion demonstrated 100% accuracy. In the presence of BBB, accuracy decreased to 87.5%, with a sensitivity of 70%. For the second criterion, accurate localization of LVOT versus RVOT occurred in 70% of cases with BBB compared with 90% in those without BBB. Conclusion In the presence of bundle branch block, commonly relied-upon ECG criteria for outflow tract PVC localization show diminished accuracy, underscoring the need to reconsider their reliability in routine clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Systematic Three‐Site Mapping for Redo Ablation of Outflow‐Tract Premature Ventricular ContractionsJournal of Arrhythmia · 2026
- Coupling Interval Variability of Outflow Tract Premature Ventricular Contractions: A Poincaré Plot-Based Assessment.Journal of cardiovascular electrophysiology · 2026
- Machine Learning‐Based Classification of Right and Left Ventricular Outflow Tract Premature Ventricular ContractionsAnnals of Noninvasive Electrocardiology · 2026
- Catheter ablation of premature ventricular complexes originating from the proximal left anterior fascicle: from electrocardiographic localization to strategy optimizationFrontiers in Cardiovascular Medicine · 2026
- Unipolar local activation time outperforms bipolar electrograms for localizing outflow tract premature ventricular contractionsEuropean Heart Journal · 2026
- Left Bundle Branch Capture During Left Bundle Branch Area Pacing: A Diagnostic Accuracy Systematic Review.Pacing and clinical electrophysiology : PACE · 2026