Patient-related complications of pulsed-field ablation catheters: A FDA MAUDE database analysis of farawave system
O Makdah, C Ursu, M bistriceanu, G Teadorescu, B Moise, A carja, A khebbaiz, E Gales,
Key points
From the paper's conclusion- Objective To analyze device- and patient-related complications with the Farawave PFA catheters using the FDA MAUDE database.
Abstract
Introduction Pulsed-field ablation (PFA) is a novel energy source that induces selective and irreversible electroporation of cardiomyocytes without collateral damage to surrounding tissues. Post-marketing safety comparisons between commercially available PFA platforms remain limited. Objective To analyze device- and patient-related complications with the Farawave PFA catheters using the FDA MAUDE database. Methods The FDA MAUDE database was queried for adverse events of commercial PFA catheters from January 1 to December 31, 2024. Reports were identified by manufacturer and FDA product codes and categorized as device malfunctions, patient injuries, or deaths. We grouped the events into categories: circulatory, neurologic, arrhythmia, life-threatening,catheter-related and others. We reported the data descriptively using total event counts and percentages. Results A total of 1480 adverse event reports related to the Farawave catheter were identified. Circulatory complications were the most frequently reported category (n = 325; 21.96%), followed by neurologic events (n = 114; 7.70%) and arrhythmic events (n = 112; 7.57%). Catheter-related complications accounted for 47 reports (3.18%), while death was reported in 23 cases (2.02%). Life-threatening events represented 25 reports (1.69%), and other organ damage was documented in 17 cases (1.15%). Within the circulatory category, pericardial effusion was the predominant event (n = 91; 28.00% of circulatory events), followed by cardiac tamponade (n = 41; 12.62%) and cardiac perforation (n = 26; 8.00%). Among neurologic complications, stroke was the most commonly reported event (n = 23; 20.18% of neurologic events), whereas transient ischemic attack accounted for 5 cases (4.39%). Regarding arrhythmic complications, ventricular fibrillation was reported in 7 cases (28.00% of arrhythmic events), and asystole in 2 cases (8.00%). Within life-threatening events, cardiac arrest represented 16 cases (64.00%). Among catheter-related complications, hemolysis was the most frequently reported event (n = 19; 40.43%). Conclusion Overall, circulatory complications particularly pericardial effusion and cardiac tamponade, constituted the largest proportion of reported adverse events associated with the Farawave catheter.Complications
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Device- and patient-related complications of pulsed-field ablation catheters: a FDA MAUDE database analysis comparing FARAWAVE and VARIPULSEEuropean Heart Journal · 2026
- Adverse Event Landscape of Pulsed Field Ablation Catheters: A Computational Review of FDA MAUDE Post-Market Surveillance Data.Reviews in cardiovascular medicine · 2026
- Real-World Safety of Two Pulsed Field Ablation Catheters for Atrial Fibrillation: A MAUDE Analysis.Pacing and clinical electrophysiology : PACE · 2026
- Reclassifying Ablation Energy Risk Profiles in Atrial Fibrillation: A Narrative-Adjudicated Comparative Analysis of the MAUDE DatabasemedRxiv · 2026
- Safety of Pulsed Field Ablation: Established Evidence, Emerging Risks, and Knowledge Gaps.Pacing and clinical electrophysiology : PACE · 2026
- Post-market individual-report phenotypes after pulsed-field ablation for atrial fibrillation in a food and drug administration database.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026