Safety of same-day discharge following pulsed field vs. thermal ablation for atrial fibrillation: a meta-analysis
M I A Bistriceanu, S S Popescu, R R Tilz
Key points
From the paper's conclusion- Conclusion In patients undergoing PFA, SDD demonstrated a safety profile comparable to that observed after thermal ablation for AF and may further enhance procedural workflow efficiency.
Abstract
Background Same-day discharge (SDD) after atrial fibrillation (AF) ablation is increasingly adopted to optimise healthcare resource utilisation without compromising safety. While established SDD protocols are largely based on thermal energy sources, pulsed-field ablation (PFA) may further streamline workflows due to shorter procedure times and a favourable safety profile. However, large-scale comparative data on energy modalities within SDD programmes remain limited. Purpose To perform a meta-analysis comparing the safety of PFA versus thermal ablation for AF ablation within established SDD protocols. Methods A systematic search of PubMed, Embase, and Cochrane databases was conducted to identify randomised controlled trials or observational studies comparing PFA with radiofrequency/cryoballon in SDD patients who underwent AF ablation. The primary endpoint was a composite of major adverse events within 30 days. Risk ratios (RR) with 95% confidence intervals (CI) were calculated using a random-effects model with the Hartung-Knapp-Sidik-Jonkman method. Results Three studies, including 1011 patients (402 PFA, 609 thermal), were included. In the PFA group, 77.5% of procedures were performed with the pentaspline catheter. In the thermal group, radiofrequency was performed in 43% of cases. SDD after PFA was not linked to an increased rate of major adverse events (RR 3.32; 95% CI: 0.63 – 17.55; I² = 0%) or all-cause mortality (RR 1.40; 95% CI: 0.15 – 13.40; I² = 0%) within 30 days compared to thermal ablation (Figure 1). The 30-day all-cause readmission rate showed no significant difference (RR 2.32; 95% CI: 0.44 – 12.30; I² = 51%) (Figure 2). Conclusion In patients undergoing PFA, SDD demonstrated a safety profile comparable to that observed after thermal ablation for AF and may further enhance procedural workflow efficiency. However, randomized controlled trials are required to confirm these findings and establish definitive conclusions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Same day discharge following pulsed field ablation for atrial fibrillation: a meta-analysisEuropean Heart Journal · 2026
- Same-day discharge after dual-energy ablation for atrial fibrillationEuropean Heart Journal · 2026
- Pulsed field versus thermal ablation for atrial fibrillation: a systematic review and meta-analysis of efficacy, safety and procedural performanceEuropean Heart Journal · 2026
- Safety and efficiency of same-day discharge after elective atrial fibrillation ablation: impact of vascular closure devices and ablation techniqueEuropean Heart Journal · 2026
- Pulsed field versus conventional thermal ablation for paroxysmal atrial fibrillation: Insights from a reconstructed individual patient data meta-analysis of randomised controlled trialsEuropean Heart Journal · 2026
- Outcomes With Pulsed Field Ablation Versus Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation: A Meta‐AnalysisJournal of Arrhythmia · 2025