Impact of the right atrial substrate on arrhythmia recurrence following atrial fibrillation ablation
N Bodagh, V Vigneswaran, A Gharaviri, I Kotadia, M Klis, K Maciunas, A Von Kietzell, S Niederer,
Key points
From the paper's conclusion- These findings suggest that perturbations in the right atrial substrate may contribute to arrhythmia recurrence following ablation.
Abstract
Background Although it is recognised that left atrial remodelling contributes to the arrhythmogenic substrate in atrial fibrillation (AF), the involvement of the right atrium remains incompletely understood. Right atrial substrate perturbations may contribute to arrhythmia recurrence following AF catheter ablation, which primarily targets the left atrium. Purpose To evaluate right and left atrial structural, functional, and electrophysiological predictors of AF recurrence following ablation and determine whether right atrial substrate perturbations independently predict recurrence risk. Methods In a multicentre, prospective, observational, cohort study, patients undergoing first-time AF ablation underwent pre-procedural cardiac magnetic resonance imaging (MRI) and intraprocedural bi-atrial electroanatomic mapping and electrophysiological assessment. Structural, functional, and electrophysiological parameters — including bi-atrial volume, ejection fraction, MRI-derived fibrosis burden, mean bipolar voltage, low voltage area, conduction velocity, wave collision percentage, and effective refractory period — were evaluated. Associations with arrhythmia recurrence were assessed using univariable Cox proportional hazards models for time to recurrence within 12 months excluding blanking period-only events. Significant predictors were examined in multivariable Cox models. Results Eighty-six patients were included, of whom 32 experienced arrhythmia recurrence. In univariable analysis, right atrial electroanatomic mapping parameters including mean bipolar voltage (HR 0.36, 95% CI 0.17–0.77, p=0.008), low voltage area percentage (HR 1.27, 95% CI 1.06–1.52, p=0.009) and wave collision percentage (HR 1.18, 95% CI 1.01–1.37, p=0.036) as well as left atrial low voltage area percentage were associated with recurrence (HR 1.15, 95% CI 1.03–1.28, p=0.016). In multivariable models adjusting each right atrial predictor for its corresponding left atrial parameter, mean right atrial voltage remained independently associated with recurrence (HR 0.33, 95% CI 0.12–0.90, p=0.031). Conclusions Reduced right atrial bipolar voltage is independently associated with arrhythmia recurrence following first-time AF ablation after adjustment for left atrial bipolar voltage. These findings suggest that perturbations in the right atrial substrate may contribute to arrhythmia recurrence following ablation. Further studies are warranted to define the role of right atrial substrate assessment in risk stratification and tailored ablation strategies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biatrial Echocardiographic Remodeling and Atrial Fibrillation Recurrence in HFpEF/HFmrEF: A Prospective Cohort Study.Biomedicines · 2026
- Arrhythmogenic substrates in atrial fibrillation and the role of ablation lesions: a longitudinal biatrial digital twin studyCardiovascular Research · 2026
- Differences between right and left atrial strain and geometric parameters in prediction of ablation outcomes for paroxysmal atrial fibrillationEuropean Heart Journal · 2026
- Reverse Cardiac and Epicardial Adipose Tissue Remodeling Following Catheter Ablation of Paroxysmal Atrial Fibrillation in HFpEF.Diagnostics (Basel, Switzerland) · 2026
- CT-Derived Periatrial Adipose Tissue Attenuation, Electroanatomic Remodeling, and Recurrence After Atrial Fibrillation AblationJournal of Clinical Medicine · 2026
- Clinical Implications of Left Atrial and Ventricular Reverse Remodeling After Atrial Fibrillation Ablation in Patients With Systolic DysfunctionJournal of the American Heart Association · 2026