Universal monitoring system vs conventional remote monitoring: 4-year extended follow-up from the nationwide EVIDENCE-RM study
N Varma, E Marijon, Serge Boveda, G Faedda, M Gentils, Y Youssfi, P Defaye, J Singh
Key points
From the paper's conclusion- The significant incremental benefit associated with UMS suggests that clinical outcomes in patients remote monitoring may vary depending on the management system used, beyond the simple transmission of device data.Unadjusted survival rate in the two cohorts
Abstract
Background Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) is recommended to improve outcomes, yet long-term real-world evidence on its sustained survival benefit remains scarce. Purpose We aimed to evaluate the 4-year impact (2019-2023) of RM activation and the incremental benefit of a Universal Monitoring System (UMS) platform on all-cause mortality. Methods We conducted a retrospective longitudinal study using the French National Healthcare System database (SNDS). All patients implanted with an ICD or CRT-D between 2019 and 2023 were included. To eliminate immortal time bias, a Cox proportional hazards model with time-varying covariates was used, where RM exposure was treated as a time-dependent status initiated at the first RM activation. Two study cohorts were analysed RM vs. no-RM and UMS vs. Conventional RM. Models were adjusted for age, sex, device model, and the Elixhauser comorbidity index (37 variables). Results A total of 84,642 patients were included (CRT-D 33.2 %; mean age 66.6 ± 12.7/ male 79.0%). In the primary study, patients with RM (n=65,869) demonstrated significantly lower mortality compared to the no-RM group (n=18,773) (18.8% vs. 27.1%, respectively). Unadjusted time-varying Cox analysis showed a 35% reduction in the instantaneous risk of death (P< 0.001). After adjustment for confounders, the survival benefit remained highly significant with a 23.5% reduction in mortality risk (HR 0.765; CI [0.74 0.80]? P<0.001). In the platform-specific analysis, UMS (n=8,026) was associated with a lower mortality rate compared to Conventional RM (n=24,301) (13.1% vs. 25.9%, respectively). Unadjusted analysis indicated a 23% decrease in the risk of death (P<0.001). Following full adjustment for confounders, including device model, the use of UMS remained associated with a significant 18% reduction in the mortality rate (HR 0.82; CI [0.76 0.88]; P<0.001) compared to manufacturer-specific solutions Conclusion This 4-year nationwide retrospective analysis confirms that RM provides a robust and sustained survival benefit. Importantly, managing RM through a UMS offers a significant incremental survival advantage of 18%. The significant incremental benefit associated with UMS suggests that clinical outcomes in patients remote monitoring may vary depending on the management system used, beyond the simple transmission of device data.Unadjusted survival rate in the two cohorts
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Remote monitoring in patients awaiting elective cardiac surgery is associated with improved clinical outcomes: a prospective service evaluationEuropean Heart Journal - Digital Health · 2026
- Effects of Remote Monitoring of Tachy-Devices: A Systematic Review and Component Network Meta-Analysis.Pacing and clinical electrophysiology : PACE · 2026
- Real-world evaluation of the positive predictive value and transmission burden of a novel implantable cardiac monitor with a remote reprogramming capability: insights from a single-center experienceFrontiers in Cardiovascular Medicine · 2026
- Diagnostic Yield and Clinical Consequences of Implantable Loop Recorder Monitoring in a Real-World Tertiary Cardiovascular Center Under Restricted Reimbursement.Healthcare (Basel, Switzerland) · 2026
- Changes in Remote Monitoring for Patients With Cardiac Implantable Electronic Devices After a Reimbursement Revision - An Interrupted Time-Series Analysis.Circulation journal : official journal of the Japanese Circulation Society · 2026
- Remote interrogation and reprogramming of CIEDs: a prospective, paired, self-controlled, non-inferiority, multicenter clinical trial — Acute phase results of the CIED-CARE studyEuropean Heart Journal · 2026