European Heart Journal

Enhancing cardiovascular consultation training with a multi-agent virtual patient framework: a multi-model comparative evaluation study

Xiaowei Xu, Tao Zhang, Y Qu, X Lu, J Li

Computational · n=560

Key points

From the paper's conclusion
  • Conclusion A multi-agent virtual patient architecture significantly improves the stability, accuracy, and clinical fidelity of cardiovascular consultation simulations.

Abstract

Background Incomplete cardiovascular history-taking and suboptimal risk-factor assessment are primary contributors to delayed diagnosis and inconsistent guideline adherence. While Large Language Model (LLM)-based virtual patients (VPs) offer a scalable solution for standardized training, single-agent systems often suffer from "hallucinations," role inconsistency, and instability in complex cardiovascular scenarios, limiting their utility in high-stakes clinical education. Purpose To develop and evaluate a Multi-Agent (MA) virtual patient framework designed to enhance structured cardiovascular consultation quality, minimize diagnostic hallucinations, and improve clinical reasoning in simulated cardiology training. Methods We developed a cardiology-specific MA virtual patient system composed of orchestrated sub-agents responsible for clinical information retrieval (RAG-supported), personality modeling, and response generation. The system was benchmarked against single-LLM baselines across seven backbone models using a standardized dataset of 560 cardiology consultation scenarios. Evaluation was conducted in two stages:Large-scale script-based benchmarking (N=560): Performance was evaluated using checklists derived from ESC guideline-relevant domain (symptom characterization, risk-factor coverage, red-flag recognition, and differential diagnosis).Pilot interactive validation: Four medical postgraduates conducted blinded consultations with five unique cardiology virtual patients to assess response accuracy, role consistency, and perceived educational impact. Results In script-based evaluation (N=560), the MA framework consistently outperformed single-LLM systems. High-capacity MA models achieved diagnostic accuracy >97% and a hallucination rate <2%, whereas single-model stability fluctuated significantly (accuracy <95%). Role-playing fidelity scores, assessed by blinded evaluators were markedly higher for MA systems (38.0–39.7/40) than for baselines (36.3–38.7/40), particularly in complex differential diagnosis. Pilot interactive validation confirmed high usability, with all participants reporting enhanced clinical reasoning awareness and supporting its integration into cardiology curricula. Conclusion A multi-agent virtual patient architecture significantly improves the stability, accuracy, and clinical fidelity of cardiovascular consultation simulations. By substantially reducing diagnostic inconsistency and clinically irrelevant output, and ensuring guideline-aligned interactions, this digital health approach provides a robust, scalable strategy to standardize early-stage cardiovascular evaluation and improve diagnostic safety.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Enhancing cardiovascular consultation training with a multi-agent virtual patient framework: a multi-model comparative evaluation study — Science Skim