European Heart Journal

A novel AI-derived digital biomarker for monitoring disease progression in ATTR-CM: first-in-trial use of a computer vision AI-ECG algorithm within a phase 3 pivotal randomized controlled trial

R Khera, P M Croon, S S Vasisht, T Bergemann, G Murtagh, J Whang, L Dhingra

Randomised · Phase III

Key points

From the paper's conclusion
  • These findings support the potential role of AI-ECG-derived prediction scores as a scalable digital biomarker for disease monitoring in clinical trials and potential routine cardiovascular care.

Abstract

Background Transthyretin amyloid cardiomyopathy (ATTR-CM) is a progressive infiltrative cardiomyopathy. Artificial intelligence electrocardiogram (AI-ECG) algorithms have emerged as powerful tools to screen for cardiomyopathies such as ATTR-CM. However, the potential of AI-ECG prediction scores to function as a quantitative digital biomarker for longitudinal disease monitoring has not been established. In the phase 3 ATTRibute-CM randomized controlled trial (RCT; NCT03860935), acoramidis, a near-complete (≥90%) transthyretin stabilizer, reduced cardiovascular mortality and cardiovascular-related hospitalizations. The trial obtained serial ECGs of enrolled participants at baseline and follow up. Purpose We report the first deployment of a computer vision AI-ECG algorithm, operating directly on ECG images without digital signal data, as a digital biomarker to prospectively monitor ATTR-CM disease progression in a RCT (ATTRibute-CM). Methods Eligible adult participants (≤90 years) with an established diagnosis of ATTR-CM based on either an endomyocardial biopsy or positive results on technetium-99m scintigraphy were enrolled in the trial. Standard 12-lead ECGs were obtained on all participants every 3 months during the study. The AI-ECG computer vision algorithm was deployed in a blinded fashion to all ECGs with intrinsic rhythms after they were fully anonymized and randomly organized. The output from the AI-ECG is a prediction score from 0 to 1. After re-linking participant identifiers and visit timing, the mean baseline AI-ECG score and the subsequent change from baseline (CFB) at month 30 (M30) were summarized. The difference in the M30 CFB AI-ECG scores between acoramidis and placebo were compared using a 2-sample t-test. Results A total of 516 baseline ECGs were analyzed. Among these, 199 acoramidis-treated and 91 placebo-treated participants had both baseline and Month 30 (M30) ECGs available for longitudinal analysis. Across study arms, baseline AI-ECG scores were higher in those with variant/mutant ATTR-CM vs wild-type (0.43 vs 0.35) and those with elevated NT-proBNP >3000 pg/mL vs <3000 pg/mL (0.39 vs 0.34) (Table). Mean (SD) baseline AI-ECG scores were 0.38 (0.21) and 0.31 (0.23) in the acoramidis and placebo arms, respectively (p-value = ns). Over 30 months of follow-up, there was a CFB in the AI-ECG score of -0.03 in the acoramidis arm versus +0.02 in the placebo arm (mean difference 0.05, p<0.05) (Figure). Conclusion An image-based AI-ECG algorithm demonstrated discrimination across clinical subgroups at baseline and detected differential longitudinal changes between acoramidis and placebo over 30 months. These findings support the potential role of AI-ECG-derived prediction scores as a scalable digital biomarker for disease monitoring in clinical trials and potential routine cardiovascular care.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers