Diagnostic yield of implantable loop recorders in routine clinical practice - a 10-year single-centre experience

A Fonseca Vazao, A Martins, M Amado, J R Pereira, C Esteves, M Baburko, J Carvalho, D Severino,

Key points

From the paper's conclusion
  • Overall, 23 patients died (6.8%), of whom 3 CV deaths.

Abstract

Background Implantable loop recorders (ILRs) are widely used in the evaluation of syncope, palpitations, and cryptogenic stroke, but real-world data on their diagnostic yield remains limited. Objective To evaluate the diagnostic yield of ILRs in a real-world population from a local health unit in Portugal. Methods Single-center retrospective cohort of patients (pts) who underwent ILR monitoring (Dec 2014-Dec 2024). Baseline clinical, electrocardiographic and echocardiographic variables and outcomes (all-cause mortality, cardiovascular (CV) mortality, heart failure (HF) hospitalization and urgent pacemaker (PM) implantation) were collected. Diagnostic findings included symptomatic sinus node disease (SND), atrioventricular (AV) node disease (high-grade AV block; complete AV block), new-onset atrial fibrillation (AF), slow AF (symptomatic ventricular pause >3s) and sustained supraventricular (SVT) or ventricular tachycardia (VT). Results A total of 340 ILRs were implanted. Annual implant numbers increased over time, peaking at 64 in 2023 (Figure 1A). Syncope was the main indication (n=274, 80.6%), followed by palpitations (n=35, 10.3%) and cryptogenic stroke (n=18, 5.3%). Patients were predominantly male (50.6%), with a mean age of 64.9±15.6 years. Baseline electrocardiograms revealed sinus rhythm in 65% and bundle branch block (BBB) in 12.8%. The median left ventricular ejection fraction was 60%. The overall diagnostic yield was 34.1%, with a median time to diagnosis of 6 months. Diagnostic yield declined markedly after the first year (Figure 1B). Among syncope pts, the diagnostic yield was 33.2%; 66 pts (72.5%) subsequently received a cardiac implantable electronic device - 64 pts received a pacemaker (16 for complete AV block, 35 for SND, 7 for high-grade AV block, 3 for bradycardia-tachycardia syndrome, 3 for slow AF) and 2 pts received an implantable cardioverter-defibrillator (ICD) for VT. Among pts monitored for cryptogenic stroke the yield was lower (16.7%), with the diagnosis of AF in 2 pts and sustained asymptomatic VT in another patient, although the findings led to therapeutic changes in 2/3 of cases. In the palpitation’s subgroup, the diagnostic yield was 48.6%, mainly SVT, with targeted treatment in 47% of diagnosed cases (Figure 2). Pts were followed for a median of 23 months [IQR 9-38]. During follow-up, 30 pts experienced adverse outcomes, including 11 urgent admissions for syncope requiring subsequent PM implantation and 3 hospitalizations for HF. Overall, 23 patients died (6.8%), of whom 3 CV deaths. Conclusion ILRs are a highly valuable diagnostic tool for the evaluation of syncope, cryptogenic stroke and palpitations. In this real-world cohort, ILRs demonstrated a good diagnostic performance, with a diagnostic yield of 34%, and most diagnoses occurring within the first year after implantation.Fig. 1:(A) Nr of ILR; (B) Time to diagnosisFig. 2:Diagnosis outcomes

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Diagnostic yield of implantable loop recorders in routine clinical practice - a 10-year single-centre experience — Science Skim