Continuous non-invasive pulmonary artery pressure assessment via seismocardiography and twin neural network
E Korsgaard, A Agam, P Sogaard, B Kjaergaard, J J Struijk, N Giordano, S Schmidt
Key points
From the paper's conclusion- These findings suggest that using SCG alone can track dynamic changes in PAP.
Abstract
Background Small and sustained increase in pulmonary artery pressure (PAP) often precede acute heart failure (HF) and are only later reflected in conventional vital signs and symptoms. Elevated PAP is currently considered as a pivotable biomarker to monitor HF decompensation as continuous invasive PAP monitoring has been shown to reduce hospitalizations and mortality. Current continuous PAP monitoring relies on invasive and costly catheter-based systems limiting the use in general HF. Seismocardiography (SCG), a non-invasive technique capturing cardiac vibrations, has shown potential for tracking cardiac hemodynamics and may allow continuous, low-cost HF monitoring to guide timely intervention and improve outcomes. Purpose To develop a non-invasive method using SCG and twin neural networks (TNN) to track changes in PAP over time using only the SCG signal. Methods Ten anesthetized pigs were subjected to alternating hypercapnia and hypoxemia. The pig returned to baseline values before a new hypercapnia or hypoxemia intervention was initiated. PAP was measured via right heart catheterization, while SCG was recorded from a sternal accelerometer. A TNN was trained to estimate relative changes in PAP by comparing SCG recordings at baseline with those recorded during the intervention. Model performance was evaluated based on correlation between the true and predicted difference between baseline and intervention PAPs using leave-one-out-strategy. Results The TNN predicted PAP changes with a mean correlation of 0.688 during hypercapnia and 0.432 during hypoxemia across the 10 pigs. The correlation was statistically significant different from 0 (p=0.0039) for hypercapnia and close to significant for hypoxemia (p=0.0580). Conclusion(s) SCG was able to non-invasively detect changes in PAP in pigs, with moderate to strong correlation to invasive measurements, particularly during hypercapnia. These findings suggest that using SCG alone can track dynamic changes in PAP. This method could potentially be utilized as a continuous, low-cost alternative to catheter-based PAP monitoring to monitor hemodynamic changes in HF patients. However, further evaluation in humans is required.Examples of model predictions over timeCorrelation plots for all models
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Noninvasive tracking of right ventricular systolic pressure via multi-channel digital auscultationEuropean Heart Journal · 2026
- A feasibility study evaluating seismocardiography for the detection of heart failure.PLOS digital health · 2026
- Quantifying changes in triaxial seismocardiography variability due to sub-optimal volume statusFrontiers in Physiology · 2026
- Dual-modal AI wearable system for geriatric AF-HF-SAS comorbidity management: a national database-backed translational studyEuropean Heart Journal · 2026
- An improved Portia spider optimized SpikeApneaNet for ECG-based sleep apnea detection with FPGA implementationScientific Reports · 2026
- reSPIRE: A wearable multimodal sensing system for monitoring ventilation, cardiovascular dynamics, and respiratory muscle activityBiosensors and Bioelectronics · 2026