Coronary motion as a functional biomarker in routine X-ray angiography
Y Moghbelan, R Tao, D Breucker, M von Scheidt, O Hayden, J Olivan Bescos, D Ruijters
Key points
From the paper's conclusion- Motion-derived representations demonstrate significant associations with established cardiovascular risk factors, supporting coronary motion as a promising functional imaging biomarker.Coronary motion-based risk predictionCoronary motion extraction from X-ray
Abstract
Background Cardiovascular disease remains a leading cause of mortality worldwide, and a considerable proportion of patients with coronary artery disease present without traditional risk factors, highlighting the need for additional functional biomarkers. Coronary artery motion observed in routine X-ray angiography reflects myocardial contraction and vascular mechanics but remains underexplored as a quantitative biomarker due to challenges in robust and scalable motion extraction. Purpose This study aimed to develop and validate a scalable deep learning framework to extract coronary artery motion from routine angiographic sequences and to evaluate associations between motion-derived representations and established cardiovascular risk factors. Methods In this retrospective study, >50,000 angiographic sequences from 1,824 patients were analysed. To reduce geometric variability, analyses were restricted to the dominant projection cluster, yielding 8,792 sequences. Nine consecutive peak-contrast frames per sequence were selected. Coronary motion between consecutive frames was quantified using a deep learning–based dense optical flow method and validated using synthetic transformations and reconstruction-based assessment on real data. Stacked motion fields were used to train a network capturing spatial and temporal coronary dynamics. Two video-based architectures were evaluated (a two-stream ResNet-152 and a transformer-based model), with the ResNet-152 demonstrating superior performance and selected for subsequent analyses. The network was trained to predict categorical clinical parameters. Results On synthetic data, motion estimation achieved a mean endpoint error of 0.50 pixels with 96.1% of displacements within one pixel. On real angiographic data, motion-based reconstruction reduced mean squared error from 1944.9 to 1710.6 and increased sensitivity from 0.49 to 0.55 compared with a no-motion baseline. Motion representations achieved higher accuracy for reduced ejection fraction (83.0% vs 53%, p<0.001), hypercholesterolaemia (68.4% vs 42%, p<0.001), hypertension (90.2% vs 68%, p<0.01), and nicotine use (81.5% vs 54%, p<0.001), with no significant improvement for diabetes. Conclusion Coronary artery motion can be extracted from routine X-ray angiography in a scalable, segmentation-free manner. Motion-derived representations demonstrate significant associations with established cardiovascular risk factors, supporting coronary motion as a promising functional imaging biomarker.Coronary motion-based risk predictionCoronary motion extraction from X-ray
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A fully automated deep learning framework for assessing left ventricular systolic function from coronary angiography with validation in acute myocardial infarctionEuropean Heart Journal · 2026
- Qualitative and quantitative assessment of deep learning-based raw data motion correction in atrial fibrillation: benefit in high heart rate and motion-prone segmentsEuropean Heart Journal · 2026
- A multiview video-text model detects obstructive coronary stenosis and predicts 1-year cardiovascular events from angiography.Nature cardiovascular research · 2026
- Clinical Applications of Artificial Intelligence in Cardiac CT: From Coronary CT Angiography to CT-Derived Fractional Flow Reserve and Myocardial Perfusion Imaging.Korean journal of radiology · 2026
- Deep learning for x-ray coronary angiography: a systematic review of methods, validation, and clinical readinessEuropean Heart Journal · 2026
- End-to-end deep learning on coronary angiographic video predicts in-stent restenosis at dual peri-procedural time pointsEuropean Heart Journal · 2026