Wrist-derived photoplethysmography features prior to and after transcatheter aortic valve implantation: Towards smartwatch-based screening for aortic valve stenosis
L R Pol, C E Jansen, N van Royen, R Edgar, J L Bonnes
Key points
From the paper's conclusion- Purpose To explore the impact of AS on wrist-derived PPG features before and after transcatheter aortic valve implantation (TAVI).
Abstract
Introduction Photoplethysmography (PPG) captures the blood volume curve under the skin, which may be altered in the presence of aortic valve stenosis (AS) due to the slower opening of the stenotic valve. If so, PPG could serve as a simple, low-cost method for remote screening of AS. Purpose To explore the impact of AS on wrist-derived PPG features before and after transcatheter aortic valve implantation (TAVI). Methods PPG data were collected at 128Hz using a PPG-sensor incorporated in a wristband worn by patients during TAVI. Data were filtered (bandpass: 0.5-7Hz) and motion artefacts removed. PPG features were calculated using the systolic peak and dicrotic notch and the median of 300 heartbeats was taken. Differences in features before and after TAVI were tested using the paired t-test or Wilcoxon signed rank test, whichever appropriate. Results In total, 121 patients were included. Patients had a median age of 79 (IQR 76-84) and the majority was male (55%). Heart rate did not differ before and after valve replacement (p=.052). Time to systolic peak was longer before TAVI (0.27 (0.25-0.30) vs 0.25 (0.22-0.28), p<.001), as was the time until dicrotic notch (0.42 (0.40-0.46) vs 0.41 (0.38-0.45), p=.005). The ratio of diastolic to systolic area under the curve decreased after TAVI (diastolic / systolic AUC: 0.49 (0.41-0.60) vs 0.57 (0.41-0.71), p=.010), indicating a relatively greater systolic contribution before the procedure. Conclusion This explorative study demonstrates differences in features of the PPG signal before and after aortic valve replacement. This is an incentive to further study the impact of AS on the PPG signal. If patients with AS can be distinguished using PPG, this may allow individuals to be screened for AS using their own smartwatch.Figure 1
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Integrating Deep PPG Representations and Digital Biomarkers for Aortic Stenosis Detection with Peri-TAVI AssessmentarXiv · 2026
- Age-associated photoplethysmographic features across systolic blood pressure strata: a cross-sectional study.Frontiers in physiology · 2026
- Photoplethysmographic Signal Analysis for Vascular Ageing Assessment.Physiological measurement · 2026
- Accuracy of Photoplethysmography-Derived Pulse Rate Variability Compared with Electrocardiography-Derived Heart Rate Variability: A Systematic Review and Meta-Analysis.Sensors (Basel, Switzerland) · 2026
- Heart rate monitoring using wrist photoplethysmography in Parkinson disease: feasibility and relation with autonomic dysfunctionJournal of NeuroEngineering and Rehabilitation · 2026
- Context-Augmented, Session-Calibrated Blood Pressure Tracking from PhotoplethysmographyarXiv · 2026