Acute myocardial infarction (AMI) vs. Non-AMI cardiogenic shock treated with microaxial flow pump support: insights from the multicenter MMERGE registry
F Bruno, V Panoulas, F Giacobbe, A Latib, R Scarsini, J Oreglia, F D'Ascenzo, A Urimarri,
Key points
From the paper's conclusion- Conversely, in non-AMI CS cohort, mortality was 34% in C, 56% in D, and 64% in E, with overlapping D/E curves.
Abstract
Background percutaneous microaxial flow pump support (mAFP – Impella®) is increasingly adopted in cardiogenic shock (CS) for its ability to actively unload the ventricles, reduce end-diastolic pressure, minimize cardiac work and augment cardiac output. However, pathophysiological differences exist between acute myocardial infarction-related CS (AMI-CS) and non-AMI-CS. Purpose To assess differences in baseline features, in-hospital complications, and outcomes after Impella implantation according to CS etiology in a real world contemporary cohort of patients with CS treated with mAFP. Methods We analyzed 449 CS patients treated with Impella from the internatonal multicenter IMMERGE registry, including 266 AMI-CS and 180 non-AMI-CS. The primary outcome was all-cause mortality at 180 days and at long term follow-up. Additional outcomes included a composite of all-cause death, durable LVAD implantation, or heart transplantation. Baseline characteristics, in-hospital complications and follow up outcomes were compared between the two groups, with further analyses stratified by SCAI shock stage. Results At baseline, AMI-CS patients were older (64 versus 52 years) and had a higher prevalence of cardiovascular risk factors (hypertension 62% vs 27%, hypercholesterolemia 57% vs 26%, diabetes 40% vs 22%). Nearly half of those presented with STEMI while 15% had NSTE-ACS. Non-AMI-CS cohort was predominantly due to dilated (48%) or ischemic (27%) ADHF in cardiomyopathy, myocarditis (20%) or postcardiotomy shock (5%). Compared with AMI-CS, non-AMI-CS patients had larger LV dimensions and more frequent right ventricular dysfunction, longer support duration (7 vs 3 days, p<0.0001) and greater need for Impella 5.0 and 5.5 (27% vs 7%). Intrahospital complications were similar, except from higher incidence of hemolysis and device thrombosis in non-AMI CS. At 180 days, mortality was higher in AMI-CS (65.7% vs 51.7%, p=0.001), a difference persisting at long-term (p=0.01). Non-AMI-CS patients had lower mortality but higher rates of LVAD (20% vs 6%, p<0.0001) and heart transplantation (19% vs 4%, p<0.0001). According to SCAI stratification, 180-day mortality in AMI-CS cohort rose progressively with advancing SCAI stage (50% in C, 69% in D, and 78% in E), showing a clear stage-dependent gradient of risk. Conversely, in non-AMI CS cohort, mortality was 34% in C, 56% in D, and 64% in E, with overlapping D/E curves. Conclusions AMI-CS and non-AMI CS treated with mAFP in real world practice have different baseline characteristics and different outcomes. In AMI-CS, Impella may facilitate myocardial recovery, but outcomes are poor if implantation is delayed to advanced shock stages. In non-AMI-CS, Impella provides a safe bridge to LVAD or transplantation. Early implantation (SCAI C) should be pursued in both settings before progression to refractory shock.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Timing of Microaxial Flow Pump Support and In-Hospital Mortality in Infarct-Related Cardiogenic Shock: The TIMING-CS Study.Journal of cardiovascular development and disease · 2026
- Outcomes of microaxial flow pump mechanical circulatory support in cardiogenic shockEuropean Heart Journal · 2026
- Impella Outcomes in Acute Myocardial Infarction Versus Non–Acute Myocardial Infarction Cardiogenic Shock: A United States Nationwide Propensity-Matched Analysis (2016–2022)Cardiology in Review · 2026
- Impella in infarction-related cardiogenic shock: evidence, complications, and implementation of microaxial LV unloading.Medizinische Klinik, Intensivmedizin und Notfallmedizin · 2026
- Differences in Escalation/De-Escalation and Outcomes in Cardiogenic Shock Types Supported With Impella ― Insights From the J-PVAD Registry ―Circulation Journal · 2025
- Bleeding and thrombotic events during micro-axial flow pump support: A European multicenter cohort studyCritical Care · 2026