Functional correlates of strain stress echocardiography
N Gaibazzi, D Tuttolomondo, Q Ciampi, L Cortigiani, G C Kane, R Arbucci, A Zagatina, E Merli,
Key points
From the paper's conclusion- Functional correlates of SE-GLS
Abstract
Background The assessment of global longitudinal strain (GLS) allows an objective, reproducible assessment of global left ventricular (LV) longitudinal function during stress echocardiography (SE). OBJECTIVES This study aimed to assess the functional correlates of SE-GLS in chronic coronary syndromes (CCS). Methods This prospective, observational, multicenter study initially screened 5779 patients (3454 [60%] male; age 64 ± 12 years; ejection fraction 59 ± 10%) with CCS. All patients underwent rest and SE (exercise, n = 3506, 60.7%; vasodilator, n =1450, 25.1%; dobutamine, n = 823, 14.2%) in 37 accredited laboratories in 16 countries. Three different strain vendors were used. The measurement of GLS (absolute values, %) was attempted at rest and during SE. Multimarker SE included regional wall motion abnormalities with wall motion score index (WMSI) in all, B-lines (4-site scan) in 5328 (92.2%) , LV contractile reserve (based on force) in 5518 (95.5%), coronary flow velocity reserve (CFVR) in 3257 (56.4%) , and heart rate reserve (HRR) in 5683 (98.3%). Results Stress GLS was successfully evaluated in 4630 patients (feasibility = 80%) with significant differences related to stressors: with exercise in 2532 patients (feasibility 72%), with vasodilator in 1404 (feasibility 97%), and with dobutamine in 694 patients (feasibility 84%). In the 4630 patients with rest and SE measurements, the absolute value of GLS increased (rest=16.8 ± 3.9% to SE=17.5 ± 4.6%, p<0.001 vs rest). Based on the SE-GLS response, 2 groups were identified: ∆GLS stress-rest increase ≥ 2 points (Group 1, n=2990) or ∆GLS <2 (n=1640) (figure 1). Patients with reduced GLS reserve also showed during SE higher values of peak WMSI, and B-lines, with higher prevalence of abnormal force-based LV contractile reserve, reduced (≤2.0) CFVR (see Table 1) Conclusions SE-GLS is feasible with all stress modalities, but the success rate decreases with tachycardia associated with exercise and dobutamine stress. A lower GLS during stress is associated with a more severe functional impairment, with multiple functional vulnerabilities during SE, with more inducible ischemia and greater pulmonary congestion, reduced LV contractile and coronary flow velocity reserve.SE-GLS responder vs non-responderTable. Functional correlates of SE-GLS
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prognostic correlates of strain stress echocardiographyEuropean Heart Journal · 2026
- Feasibility analysis of longitudinal strain assessment in patients undergoing contrast and non-contrast enhanced stress echocardiographyEuropean Heart Journal · 2026
- Global longitudinal strain (GLS) changes during dobutamine stress echocardiography as an indicator of coronary artery diseaseEuropean Heart Journal · 2026
- Correlation and systematic bias between CT-derived and echocardiography-derived left ventricular global longitudinal strain: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Left ventricular strain measured by feature-tracking cardiac magnetic resonance imaging and 2D speckle-tracking echocardiography in chronic ischemic heart disease: an intermodality agreement studyJournal of Cardiovascular Imaging · 2026
- Left atrial volume index during rest and stress echocardiography predicts survival in patients with chronic coronary syndromeEuropean Heart Journal · 2026