Test-retest reproducibility of three-dimensional left ventricular strain by transthoracic speckle-tracking echocardiography
C Goult, C Johnson, S Donker, H Haibe, E Verhoeven, N Sculthorpe, F Place, J Maxwell,
Key points
From the paper's conclusion- Purpose To assess the test-retest reproducibility from repeated acquisitions of multiplanar 3D-STE derived LV strain parameters using transthoracic echocardiography in healthy adults.
Abstract
Background Speckle-tracking echocardiography provides quantitative assessment of left ventricular (LV) myocardial strain and is widely applied in clinical practice. Conventional two-dimensional approaches are limited primarily to longitudinal strain assessment. Three-dimensional speckle-tracking echocardiography (3D-STE) enables multiplanar evaluation of LV mechanics, including longitudinal, circumferential, radial, area, and torsional strain. This technique has the potential to offer enhanced sensitivity and specificity for LV structural and functional assessment in clinical populations allowing for serial assessment and optimal patient management. However, data on the reproducibility of repeated 3D strain acquisitions remain limited. Purpose To assess the test-retest reproducibility from repeated acquisitions of multiplanar 3D-STE derived LV strain parameters using transthoracic echocardiography in healthy adults. Methods Twenty-eight healthy adult volunteers underwent two sequential transthoracic echocardiographic examinations performed two hours apart. Participants were instructed to avoid exercise and caffeine on the testing day, abstain from alcohol for at least 24 hours and recreational drugs for 3 days prior to the visit, and refrain from eating for ≥2 hours before arrival. Measurements were scheduled after 10:00 AM to reduce potential influence of the cortisol awakening response. Three-dimensional strain and volumetric datasets were acquired during each examination. Offline analysis was performed to derive global peak 3D longitudinal, circumferential, radial, area, and torsional strain. Image analysis was blinded, with scan pairing concealed until completion. Reproducibility was assessed using intraclass correlation coefficients (ICC), coefficients of variation (CoV), one-way ANOVA, and Bland–Altman analysis. Results Minimal systematic bias was identified for all of the 3D-STE derived measures of strain (P>0.05 and Bias -0.8 to 1.25). Good to excellent agreement was observed for global 3D longitudinal, radial, and area strain parameters (ICCs: 0.71-0.8; CoVs: 9-11%). Circumferential and torsional strain demonstrated weak to moderate agreement for test-retest reproducibility (ICCs: 0.49 and 0.3; CoVs: 13% and 46% respectively). Conclusion Repeated acquisition of multiplanar 3D longitudinal, radial, and area strain demonstrates strong reproducibility in healthy adults supporting their suitability for serial assessment in both clinical and research settings. In contrast, circumferential and torsional strain parameters showed comparatively lower reproducibility, warranting cautious interpretation and further methodological refinement before widespread application.Data Table Repeated Acquisition
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inter-vendor agreement and test-retest reproducibility of right ventricular and left atrial strain measurements using two-dimensional speckle-tracking echocardiographyEuropean Heart Journal · 2026
- Reproducibility of fetal global longitudinal strain measured with speckle tracking echocardiography using a fixed cardiac cyclePLoS ONE · 2026
- Right Ventricular Function Assessed by Speckle Tracking Echocardiography in Patients Undergoing Transcatheter Pulmonary Valve Replacement.Pediatric cardiology · 2026
- Qualitätssicherung und Reproduzierbarkeit der fetalen 2D-Speckle-Tracking-EchokardiographieDie Gynäkologie · 2026
- Right Ventricular Longitudinal Strain by Speckle Tracking Echocardiography for Risk Stratification in Tricuspid Regurgitation: A Narrative ReviewJournal of Cardiovascular Development and Disease · 2026
- Multimodality Cardiac Strain: A Practical Framework for Acquisition, Validation, Interpretation, and Reporting across Echocardiography, Cardiac Magnetic Resonance and Computed TomographyEuropean Heart Journal - Imaging Methods and Practice · 2026