European Heart Journal

Screening performance of a deep learning model versus an automated wall thickness score in biopsy-proven cardiac amyloidosis

Y Nomura, Y Hirata, S Nishio, Y Saijo, R Nonaka, N Yamaguchi, R Zheng, Y Okushi,

Computational · n=171

Key points

From the paper's conclusion
  • These findings suggest that AI-CNN may serve as a practical echocardiographic screening tool to support early detection of CA in routine clinical practice.Diagnostic Comparison of Two AI Models

Abstract

Background Cardiac amyloidosis (CA) is a progressive cardiomyopathy associated with poor prognosis. The recent emergence of disease-modifying therapies has underscored the importance of early diagnosis. Because definitive diagnosis requires multiple tests, an accessible screening approach is essential. Echocardiography plays a pivotal role in screening. An artificial intelligence (AI)-based fully automated echocardiographic analysis system has been developed to detect CA from an apical four-chamber (A4C) cine clip using a deep learning model. Purpose To compare the screening performance of a deep learning model (AI-CNN) with a model that determines CA by calculating an increased wall thickness score from AI-derived automated measurements (AI-IWTS), using endomyocardial biopsy as the reference standard. Methods We retrospectively screened 171 consecutive patients who underwent endomyocardial biopsy at our institution between 2016 and 2025. Patients with AI-measured left ventricular (LV) wall thickness ≥ 12 mm were included in the analysis because this threshold is required for both AI-CNN and AI-IWTS. CA was defined as amyloid protein positivity on pathological examination. Diagnostic performance was evaluated by sensitivity, specificity, predictive values, and c-index with 95% confidence intervals. Paired classifications were compared using McNemar’s test. Results Among the 92 patients with AI-measured LV wall thickness ≥ 12 mm, 58 had biopsy-confirmed CA, including 48 with transthyretin amyloidosis (ATTR), 9 with light-chain amyloidosis (AL), and 1 with apolipoprotein A-I amyloidosis (ApoA-I). AI-CNN demonstrated a c-index of 0.82 (95% CI 0.72–0.89), with a sensitivity of 98% and a specificity of 65%. AI-IWTS demonstrated a c-index of 0.59 (95% CI 0.48–0.69), with a sensitivity of 26% and a specificity of 91%. Positive predictive value (PPV) was 83% for both methods, while negative predictive value (NPV) was higher for AI-CNN than for AI-IWTS (96% vs. 43%). McNemar’s test showed a significant difference in classifications between the two methods (P<0.001). Conclusions In a biopsy-referenced cohort selected by AI-measured LV wall thickness ≥ 12 mm, AI-CNN showed higher sensitivity and discrimination than AI-IWTS. These findings suggest that AI-CNN may serve as a practical echocardiographic screening tool to support early detection of CA in routine clinical practice.Diagnostic Comparison of Two AI Models

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers