Right ventricular pressure–strain–volume loop–derived myocardial work as a marker of contractility before and after transcatheter tricuspid valve intervention
A Fabian, H Kempton, A Ferencz, L Stolz, T Stocker, L Weckbach, P M Doldi, J Da Rocha E Silva,
Key points
From the paper's conclusion- We further adjusted GCW to instantaneous RV volumes (GCWv) and constructed PSV loops. (Figure) Results Among the 50 patients with severe TR, T-TEER resulted in significantly lower RV volumes (end-diastolic volume from 183±59 to 143±51 mL, p<0.001), RV EF (from 48±10 to 36±10%, p<0.001, and TAPSE (from 18±4 to 16±5 mm, p=0.002).
Abstract
Background Comprehensive assessment of right ventricular (RV) function is pivotal in patients with severe tricuspid regurgitation (TR) undergoing tricuspid transcatheter edge-to-edge repair (T-TEER). However, conventional echocardiographic parameters, including three-dimensional echocardiography (3DE) and speckle-tracking-derived markers, are inherently load-dependent and may not adequately reflect RV contractile reserve, particularly under the markedly altered loading conditions associated with severe TR and following T-TEER. Pressure-strain-volume (PSV) loop-derived myocardial work integrates preload, afterload, and chamber geometry within a unified hemodynamic framework and, therefore, may better reflect load-independent indices of RV contractility. Aims Accordingly, we aimed to determine whether RV PSV loop–derived myocardial work correlates with pressure-volume (PV) loop indices of contractility, and to assess acute changes in RV mechanics in patients undergoing T-TEER. Methods In 50 patients undergoing T-TEER, RV pressure waveforms were acquired intraprocedurally, immediately before and after device implantation, with simultaneous 3DE for RV volumes, to generate RV PV loops and to derive end-systolic elastance (Ees). Conventional echocardiographic metrics, such as tricuspid annular plane systolic excursion (TAPSE) and ejection fraction (EF), were also obtained. Then, to obtain RV pressure-strain (PS) loops and global myocardial constructive work (GCW), RV pressure and 3DE-derived RV longitudinal strain tracings were combined. We further adjusted GCW to instantaneous RV volumes (GCWv) and constructed PSV loops. (Figure) Results Among the 50 patients with severe TR, T-TEER resulted in significantly lower RV volumes (end-diastolic volume from 183±59 to 143±51 mL, p<0.001), RV EF (from 48±10 to 36±10%, p<0.001, and TAPSE (from 18±4 to 16±5 mm, p=0.002). Conversely, RV contractility derived from PV loop analysis significantly increased after the procedure (Ees: from 0.38 [0.29-0.47] to 0.46 [0.36-0.55] mmHg/mL, p=0.008). While PS loop-derived GCW (from 615 [439-881] to 549 [394-756] mmHg%, p=0.007) showed significantly lower values after T-TEER, values of PSV loop-derived volume-adjusted GCWv (from 180 [106-275] to 180 [92-256] mmHg%/mL, p=0.295) remained similar after the procedure. Importantly, although TAPSE (r=0.21, p=0.049), RVEF (r=0.29, p=0.004), and GCW (r=0.37, p<0.001) correlated modestly with Ees, volume-adjusted GCWv (r=0.62, p<0.001) showed a stronger correlation with RV contractility. Conclusions In the setting of acute RV unloading following successful T-TEER, pressure-volume loop-derived Ees demonstrated improved contractility. Using our novel PSV loop approach, volume-adjusted global constructive work showed a stronger association with contractility and more accurately captured intrinsic RV mechanics than conventional, load-dependent echocardiographic indices.Figure
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Longitudinal changes in right ventricular mechanics after tricuspid transcatheter edge-to-edge repairEuropean Heart Journal · 2026
- Acute impact on right ventricular function following orthotopic transcatheter tricuspid valve replacement. Insights from deformation imaging and non-invasive pressure–volume analysisEuropean Heart Journal · 2026
- Right atrial–right ventricular coupling drives decongestion and residual regurgitation after transcatheter tricuspid repairEuropean Heart Journal · 2026
- Impact of transcatheter tricuspid valve replacement on regional right ventricular contraction patternsEuropean Heart Journal - Valvular and Structural Heart Disease · 2026
- Impact of right ventricular-pulmonary artery coupling on outcomes in tricuspid regurgitation – insights from the international TRIGSTRYEuropean Heart Journal · 2026
- Impact of residual tricuspid regurgitation after transcatheter tricuspid therapies on right and left ventricular mechanics: insights from a case series.European heart journal. Case reports · 2026