Utility of multi-expert approach for validation of AI in echocardiography
S Chawla, G Almeida, T S J Ng, C Stowell, J Jevsikov, C Manisty, M Zolgharni, M Shun-Shin,
Key points
From the paper's conclusion- We study a multi-expert approach that may offer richer and clearer evaluation results.
Abstract
Background Historically, automatic measurement methods were validated by comparison to an expert human measurement. We study a multi-expert approach that may offer richer and clearer evaluation results. Purpose To evaluate multi-expert consensus as a reference to permit evaluation of AI performance that may be superhuman. Methods Six human experts, with mutual blinding, each directly measured 59 echocardiographic variables in 100 echocardiograms, and a further 113 variables were derived algebraically from these. An AI system also measured these variables. For each variable, in each echocardiogram, we could therefore calculate how far Expert 1 was from the consensus of the other 5, and how far the AI was. We could then do the same for Expert 2, 3, 4, 5, and 6 in turn. This gave, for each variable, ~600 “expert deviations from consensus of 5 other experts”, and ~600 “AI deviations from consensus of 5 human experts”, which could then be compared by F-test. We tested how informative this analysis would be with fewer experts, by reducing the dataset accordingly. Finally, we tested a simple statistic that might allow unbiased evaluations even when some experts had missing data for some studies: comparison of distribution of pairwise differences in human-human versus AI-human pairings. Results When we reduced the dataset to only two human experts, the AI appeared to perform similarly to experts. For example, for LVEF, AI-human variance 26.3%², human-human variance 24.5%², ratio of variances = 1.07, p=.74 by F-test. However, when we increased the dataset to 3 experts the ratio of variances became 1.03, p=.88. With 4 experts, ratio = 0.86, p=.46. With 5 experts, ratio = 0.60, p=.01. With 6 experts, ratio = 0.46, p<.001 (Figure 1 left). Of the 174 variables, with only 2 experts it was evident that the AI performed better than expert in 2/174 variables. With 3 experts, 18/174. With 4 experts, 25/174. With 5 experts, 32/174. With 6 experts, 40/174 (Figure 1 right). Finally, the simple pairwise difference analysis measured performance without bias, even when 1%, 2%, 5%, 10%, 20% and 50% of the expert data are removed at random. Each run gave a slightly different ratio between AI-human and human-human differences, and this dispersion increased as data removal became more extensive (p<0.001), but the findings remained unbiased: centred on the true findings (full dataset). Figure 2 shows results for LVEF; other variables showed the same pattern. Conclusion AI echocardiographic measurements should be validated against multiple, mutually blinded, experts. This allows identification of AI methods that deliver better measurement performance than that delivered by any individual expert, which is increasingly possible with newer technologies. If a dataset has gaps, the pairwise difference comparison (between human-human and AI-human pairings) continues to provide a valid result and is easy to display and understand.Figure 1Figure 2
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Origin of apparently-improved measurement error with artificial intelligence in EchocardiographyEuropean Heart Journal · 2026
- Artificial Intelligence for Automated Continuous Quantification of Left Ventricular Ejection Fraction From Standard Adult Transthoracic Echocardiography: A Systematic Review.Cureus · 2026
- Automated echocardiography image quality assessment and its association with AI performancemedRxiv · 2026
- AI-aided echocardiographic quantification improves efficiency across operator experience levels: a prospective clinical trialEuropean Heart Journal · 2026
- Deep learning-based echocardiography for cardiac assessment: a systematic literature review and meta-analysisEuropean Heart Journal - Digital Health · 2026
- Artificial Intelligence Across the Echocardiographic Workflow: A Narrative Review for Clinicians.Cureus · 2026