European journal of orthodontics

Development and evaluation of a novel automated segmentation approach for mandibular cortical bone and teeth in cone-beam computed tomography using nnU-net.

Warat Hatsadaloi, Takeshi Ogasawara, Masayoshi Uezono, Takaaki Sugino, Nicha Ungvijanpunya, Yoshikazu Nakajima, Keiji Moriyama

Department of Maxillofacial Orthognathics, Division of Maxillofacial and Neck Reconstruction, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan. · Department of Mechanical and Systems Engineering, Chukyo University, 101-2 Yagoto Honmachi, Showa-ku, Nagoya 466-8666, Japan.

Key points

From the paper's conclusion
  • The proposed nnU-Net tool produced segmentations of mandibular cortical bone and lower teeth from CBCT in close agreement with a single-observer reference standard. By segmenting cortical bone as an explicit class, it enables visualization of relative cortical thickness at candidate TAD sites; the anatomical accuracy of thickness measurements derived from it has not yet been validated, and because CBCT grayscale is not standardized, such values are relative rather than absolute. These proof-of-concept results require multicenter, multivendor validation and improvements for thin cortex and metal-artifact regions before clinical adoption.

Abstract

INTRODUCTION: Characterizing mandibular cortical bone and adjacent tooth roots is essential for safe temporary anchorage device (TAD) placement. Manual cone-beam computed tomography (CBCT) segmentation is time-consuming, and existing automated pipelines output a single mandible label without separating cortical from cancellous bone. This study developed and evaluated an nnU-Net tool that segments mandibular cortical bone and individual lower teeth from CBCT. METHODS: A total of 113 CBCT scans were split into 90 training and 23 evaluation cases. Manual segmentations of cortical bone and 16 lower teeth were produced by a single annotator after structured calibration with a senior rater on a 23-case subset, and served as a single-observer reference standard. A Residual-Encoder nnU-Net was trained with 5-fold cross-validation and ensemble at inference. Performance was evaluated by precision, recall, Dice similarity coefficient (DSC), 95th-percentile Hausdorff distance (HD95) and Normalized Surface Dice (NSD), and compared with human inter-rater agreement. RESULTS: Calibration achieved a post-washout Dice score of 95.53%. Against the reference standard, the model achieved 98.1% DSC for cortical bone and 95.9% for lower teeth, with HD95 of 0.25 mm and 0.74 mm respectively. Cortical bone NSD was 99.5% at 0.5 mm and 92.9% at 0.3 mm tolerance. Agreement between the model and an independent rater did not differ significantly from that between two calibrated raters. Inference took ∼13 s per scan, or 70 s with the five-model ensemble. Failures concentrated in severe metal artifact and thin cortical bone. CONCLUSIONS: The proposed nnU-Net tool produced segmentations of mandibular cortical bone and lower teeth from CBCT in close agreement with a single-observer reference standard. By segmenting cortical bone as an explicit class, it enables visualization of relative cortical thickness at candidate TAD sites; the anatomical accuracy of thickness measurements derived from it has not yet been validated, and because CBCT grayscale is not standardized, such values are relative rather than absolute. These proof-of-concept results require multicenter, multivendor validation and improvements for thin cortex and metal-artifact regions before clinical adoption.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers