The C-MIC II Follow-Up Study: Safety and Efficacy Results 12 months After Deactivation of Cardiac Microcurrent Therapy.
Jesus E Rame, Dragana N Kosevic, Tamara Kovacevic-Preradovic, Sasko Jovev, Marija Zdravkovic, Nermir Granov, Tanja Popov, Igor Rudez,
Bruce and Robbi Toll Heart and Vascular Institute, Thomas Jefferson University, Philadelphia, PA, USA. · Cardiovascular Institute Dedinje, Belgrade, Serbia.
Key points
From the paper's conclusion- Among patients previously treated with C-MIC device, improvements in LVEF, 6MWD, NYHA class and KCCQ-OSS were sustained, with a favorable safety profile 12 months post-deactivation.
Abstract
BACKGROUND: The C-MIC II trial demonstrated benefits of 6 months of cardiac microcurrent (C-MIC) therapy in patients with non-ischemic heart failure with reduced ejection fraction (HFrEF). The prospective C-MIC II Follow-Up Study evaluates safety and efficacy outcomes post-device deactivation. METHODS: Primary safety-related endpoints included all-cause, cardiovascular and device-related mortality and hospitalizations and adverse events (AEs). Secondary efficacy-related endpoints included changes in left ventricular ejection fraction (LVEF), Kansas City Cardiomyopathy Questionnaire Overall Summary Score (KCCQ-OSS), 6-minute walk distance (6MWD), New York Heart Association (NYHA) class and device reactivation rate. Here, we report 12-month results comparing the 6-month time-point (at the end of active therapy) with the 18-month time-point (12 months post-deactivation). RESULTS: Of 32 eligible patients, 31 (97%) were enrolled. At 12 months post-device deactivation, 3 patients (10%) were hospitalized and 1 died (3%); none were device-related. One device-related AE occurred and resolved completely. Improvements in LVEF (vs pre-implantation: +6%; 95% CI 5-8; p<0.0001) and KCCQ-OSS (vs pre-implantation: +43 points; 95% CI 36-49; p<0.0001) were sustained and unchanged from 6 months (LVEF: -0.1%; 95% CI -2-2; p=0.87; KCCQ-OSS:-2; 95% CI -8-4; p=0.49). The 6MWD remained improved (vs pre-implantation: +150 m; 95% CI 109-191; p<0.0001), with a modest decrease (-31 m; 95% CI -56- -7; p=0.013) from 6 months. Improvements in NYHA class (≥1-class improvement in 77% patients) were sustained. Three (10%) patients required device reactivation. CONCLUSION: Among patients previously treated with C-MIC device, improvements in LVEF, 6MWD, NYHA class and KCCQ-OSS were sustained, with a favorable safety profile 12 months post-deactivation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microcurrent Therapy in Cardiac Repair: Bridging Mechanistic Biology and Clinical Evidence.Circulation. Heart failure · 2026
- Multipoint left ventricular pacing benefit to cardiac resynchronization therapy of heart failure; 5-year survival study (HUMVEE)European Heart Journal · 2026
- Role of Cardiac Magnetic Resonance in Predicting Response to Cardiac Resynchronization Therapy: A Systematic Review and Meta‐AnalysisClinical Cardiology · 2026
- Left ventricular ejection fraction recovery under contemporary quadruple guideline-directed therapy and the need for ICD/CRT-D implantation in HFrEF: a retrospective single-center cohort study.Expert review of cardiovascular therapy · 2026
- Effect of mHealth on the prognosis of patients with heart failure according to left ventricular ejection fraction: subanalysis of the HERMeS TrialEuropean Heart Journal · 2026
- A novel magnetically levitated intrapericardial left ventricular assist system in advanced heart failure—2-year results from a prospective, multi-centre studyEuropean Journal of Cardio-Thoracic Surgery · 2026