科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ European Journal of Heart Failure2026-03-16· Medicine

Long-term safety and performance of an implantable IVC sensor for congestion-guided management in heart failure: 12-month results from the FUTURE-HF trial portfolio

Kevin Damman, Nir Uriel, Mandeep R Mehra, Jeffrey Testani, M F Marat Fudim, Kunjan Bhatt, Rami Kahwash, Trejeeve Martyn, Scott Feitell, George Khabeishvili, Petr Neuzil, Gabriel Sayer, Irakli Gogorishvili, Chris Critoph, Faisal Sharif, Ian Loke, RS Gardner, Ondřej Toman, Andrew Flett, Jasper J Brugts, Ali Vazir, Teresa Buxó, Alastair Gray, Barry R. Greene, PR Kalra

原始摘要(英文原文)· Original abstract
AIMS: Congestion signals heart failure progression and drives decompensation. Reliable management strategies remain poorly developed. We evaluated 12-months of congestion-guided clinical management following implantation of an inferior vena cava (IVC) sensor. METHODS AND RESULTS: Data were combined from two prospective studies (FUTURE-HF and FUTURE-HFII) (N=65, mean age 65.7±9.5 years; 75.4% NYHA III; 90.8% HFrEF). Patients recorded daily IVC parameters. Adjudicated safety outcomes, sensor-derived IVC area measurement versus CT imaging, medication adjustments, and clinical outcomes at 12-months were analysed.No adjudicated device or procedure-related serious adverse events occurred. Excellent correlation was observed between sensor-derived and CT-derived IVC area (n=44; R2=0.97; mean relative error <5%). Patient adherence was 93% and a sustained, significant reduction in IVC area was observed (8.1%, p<0.005), correlated with clinical improvements (p<0.001), despite no significant change in body weight. Improvements were observed in NYHA functional class (Class III: 74.5% improved to 40.0%; p<0.01) and NT-proBNP (median 1697 reduced to 998 ng/L; p<0.001). HF events (HFEs) were lower post-implant (0.31/year, 1.67/year pre-implant; 84.5% relative reduction; rate ratio: 0.18; 95% CI: 0.08-0.29). Medication adjustments (n=415) included diuretic titration (57%) and increased use of guideline directed medical therapy from baseline to 12-months (28%). CONCLUSIONS: Congestion management through ambulatory IVC monitoring demonstrated excellent safety, sustained accuracy, and high levels of patient adherence at 12-months after sensor implantation. This was associated with improved HF congestion status and a lower observed rate of HFEs, supporting investigation of congestion-guided management using IVC monitoring in a pivotal randomized clinical trial.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Long-term safety and performance of an implantable IVC sensor for congestion-guided management in heart failure: 12-month results from the FUTURE-HF trial portfolio — 科研速览 Science Skim