Electrosurgical septotomy across the full spectrum of aortic dissection.
Gabriel Weiss, Hubert Trnka, Sebastian Tauber, Emely Manville, Zsuzsanna Arnold, Bernhard Winkler, Sandra Folkmann, Martin Grabenwöger
Department of Cardiovascular and Vascular Surgery, Klinik Floridsdorf, Vienna Health Association (Wiener Gesundheitsverbund), Brünner Straße 68, 1210 Vienna, Austria. · Department of Interventional Radiology, Klinik Floridsdorf, Vienna, Austria.
Key points
From the paper's conclusion- Conclusions Electrosurgical septotomy was feasible across the full spectrum of aortic dissection and, in selected patients, as stand-alone treatment for malperfusion, using standard electrosurgical equipment.
Abstract
OBJECTIVES: Transcatheter electrosurgical septotomy divides the dissection membrane to reconstitute a single aortic lumen. Reported experience is largely confined to chronic post-dissection aneurysms. We assessed the technique across the full spectrum of descending aortic dissection, including stand-alone treatment of malperfusion. METHODS: Retrospective intention-to-treat analysis of 21 consecutive patients scheduled for septotomy between June 2022 and May 2026. The membrane was crossed by needle re-entry and divided with an electrified through-and-through guidewire at 40-60 W under fluoroscopy, without routine intravascular ultrasound or image fusion. A perfused-lumen index (perfused lumen divided by total aortic diameter) was measured before and after the procedure. RESULTS: Septotomy was performed in 20 of 21 patients (technical success 95% on an intention-to-treat basis). Indications were landing-zone preparation (57%), malperfusion (33%), preparation for open repair and true-lumen collapse. Malperfusion resolved in all 7 patients treated for that indication, and the perfused-lumen index rose from a median of 0.16 to 0.98 (18 patients, P < 0.001). There was no stroke, spinal cord ischaemia or retrograde type A dissection. Thirty-day, in-hospital and overall mortality were 10%, 14% and 19%, with one fatal delayed aortic rupture and no intraprocedural death. Three unplanned reinterventions occurred; median follow-up was 5.1 months. CONCLUSIONS: Electrosurgical septotomy was feasible across the full spectrum of aortic dissection and, in selected patients, as stand-alone treatment for malperfusion, using standard electrosurgical equipment. Given the small heterogeneous cohort and short follow-up, these findings demonstrate feasibility rather than durability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transcatheter Electrosurgical Aortic Septotomy Across the Spectrum of Type B Aortic Dissection: Feasibility, Technical Lessons, and Bailout Strategies.EJVES vascular forum · 2026
- Endovascular Management With a Fenestration Technique of an Iatrogenic Thoracic Chronic Type B Aortic Dissection.Cureus · 2026
- A BENCHTOP PLATFORM FOR EVALUATING SEPTOSTOMY IN AORTIC DISSECTION.Proceedings of the ... Design of Medical Devices Conference. Design of Medical Devices Conference · 2026
- Native Aorta Non-Touch Total Arch Hybrid Repair for Residual Aortic Dissection after Hemiarch Replacement.Annals of vascular diseases · 2026
- Intraoperative intravascular ultrasound assessment of branch vessel malperfusion to guide acute intervention in acute type A aortic dissection.JTCVS techniques · 2026
- David-V Procedure Combined with Zone 2 Arch Replacement for Acute Stanford Type A Dissection.Methodist DeBakey cardiovascular journal · 2026