Cardiac magnetic resonance evaluation of valve function after Sapien versus Myval transcatheter aortic valve implantation: A COMPARE-TAVI 1 substudy
Alexandra Amalie Uglebjerg Pedersen, Won Yong Kim, Lene Hüche Nielsen, Henrik Nissen, Philip Freeman, Troels Thim, Evald Høj Christiansen, Mariann Tang Jensen,
Key points
From the paper's conclusion- Conclusion CMR demonstrated only minor aortic regurgitation with both THV series, but lower ARF was observed with Sapien compared with first-generation Myval, whereas EOA was larger with second-generation Myval Octacor than with Sapien.
Abstract
Background New transcatheter heart valves (THVs) are continually introduced for transcatheter aortic valve implantation (TAVI), often without robust early haemodynamic data. Cardiac magnetic resonance (CMR) imaging offers quantification of aortic regurgitation fraction (ARF) and effective orifice area (EOA), key markers of THV performance. Aims This study aimed to compare CMR-derived ARF and EOA between patients randomized to treatment with Sapien 3/Sapien 3 Ultra or Myval/Myval Octacor THVs in the COMPARE-TAVI 1 trial. Methods and Results In this prespecified multicentre substudy, 387 patients undergoing TAVI at three Danish sites were enrolled. Of these, 327 patients (84.5%) underwent phase-contrast CMR one-month post-TAVI. Haemodynamic performance, including ARF and EOA, was compared between Sapien 3/Sapien 3 Ultra, Myval, and Myval Octacor THVs. Aortic regurgitation (AR) was classified according to Valve Academic Research Consortium 3 (VARC-3) criteria. First-generation Myval showed higher rates of VARC-3 categorical AR and greater absolute median ARF compared with Sapien THVs (ARF 7% [IQR 5-11] vs. 5% [3-8]; p=0.004). In contrast, second-generation Myval Octacor exhibited significantly larger median EOA than Sapien THVs (1.8 cm2 [IQR 1.5-2.1] vs. 1.6 cm2 [1.4-1.9]; p=0.033) with comparable ARF. When pooling generations, Sapien had lower ARF than Myval THVs, while EOA did not differ significantly. Moderate or greater AR occurred in one patient (0.3%); the remainder had trace to mild-moderate AR. Conclusion CMR demonstrated only minor aortic regurgitation with both THV series, but lower ARF was observed with Sapien compared with first-generation Myval, whereas EOA was larger with second-generation Myval Octacor than with Sapien.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- One-Year Outcomes of Myval Versus Contemporary Transcatheter Heart Valves in Severe Aortic Stenosis: A Systematic Review and Meta-Analysis.Cardiology in review · 2026
- Real-World Comparison of Balloon-Expandable Valves for Transcatheter Aortic Valve Replacement: Data From the Aortic+Mitral TRAansCatheter Valve Registry.Structural heart : the journal of the Heart Team · 2026
- Updated systematic review and meta-analysis comparing Myval versus Sapien 3 transcatheter heart valves in severe aortic stenosis: focus on early and one-year mortality.Acta cardiologica · 2026
- Bioprosthetic valve performance of transcatheter aortic valves.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2026
- Balloon- Versus Self-Expanding Transcatheter Valves for Failed Small Surgical Aortic Bioprostheses: 3-Year Results of the LYTEN TrialCirculation Cardiovascular Interventions · 2026
- Transmitral mean pressure gradient after transcatheter aortic valve replacement and late mortalityEuropean Heart Journal · 2026