Feasibility of coronary alignment in TAVI with balloon-expandable valves: insights from a COMPARE-TAVI 1 substudy.
Rebekka Vibjerg Jensen, Bjarne Linde Nørgaard, Troels Thim, Evald Høj Christiansen, Jesper Møller Jensen, Christian Juhl Terkelsen
Department of Cardiology, Aarhus University Hospital, Palle-Juul Jensens Blvd 99, Aarhus N 8200, Denmark.
Key points
From the paper's conclusion- Crimping BEV neo-commissures at predefined angles did not increase coronary alignment; however, the majority of patients treated with BEVs were still considered eligible for redo-TAVI.
Abstract
BACKGROUND: Coronary alignment may be an important prerequisite for redo-transcatheter aortic valve implantation (TAVI) and may be achieved with balloon-expandable valves (BEV) by intentional orientation of neo-commissures during crimping. AIMS: The aim of this study was to evaluate whether coronary alignment is possible during implantation of BEVs and to assess the risk of coronary obstruction limiting the feasibility of redo-TAVI. METHODS: On post-TAVI CT scans available in 375 patients enrolled in the COMPARE-TAVI 1 study, we assessed coronary alignment defined by neo-commissure-to-coronary-angles and assessed coverage of coronary ostia by the THV frame and valve-to-aorta distance.Patients were randomized to treatment with Sapien 3 (Group A) or Myval (Group B) with random orientation of neo-commissures during valve crimping (Period 1), or Sapien 3 (Group C) or Myval Octacor (Group D) (Period 2), where intentional orientation of neo-commissures during crimping was attempted according to pre-TAVI CT-scan. RESULTS: Left main alignment or mild misalignment occurred in 50%, 51%, 47%, and 55% of patients in groups A, B, C, and D, P = .33, and right coronary alignment or mild misalignment occurred in 52%, 62%, 54%, and 53%, P = .53. The proportion of patients considered feasible for redo-TAVI defined as a) no coronary coverage by the THV frame, b) coronary coverage but VTA ≥2 mm, or c) coronary coverage and VTA <2 mm but coronary alignment optimal or only mild misalignment, was 81%, 78%, 80%, 87% in groups A, B, C, and D, P = .33. CONCLUSIONS: Crimping BEV neo-commissures at predefined angles did not increase coronary alignment; however, the majority of patients treated with BEVs were still considered eligible for redo-TAVI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Landmark-based low implantation using a balloon-expandable valve to avoid sinus sequestration during redo transcatheter aortic valve implantation: a case report.European heart journal. Case reports · 2026
- Accuracy of Virtual Circle Method and Valve-to-Aorta Distance Change After Redo-TAVR: Multicenter Paired CT Analysis.Circulation. Cardiovascular interventions · 2026
- Commissural and Coronary Alignment Strategies in Transcatheter Aortic Valve Replacement: Success Rate and RisksEuropean Cardiology Review · 2026
- Optimization of Commissural Alignment Using an Anatomy-Tailored Method for a Supra-Annular Self-Expanding Transcatheter Heart Valve.JACC. Asia · 2026
- Clinical Decision-Making in High-Risk Cross-Platform Redo-TAVI: Pre-Emptive Coronary Wiring and Chimney StentingCardiovascular Medicine · 2026
- IVUS-Guided UNICORN Leaflet Modification During Redo TAVR to Prevent Coronary Obstruction.JACC. Case reports · 2026