Clinical outcomes of second-generation intra-annular self-expanding transcatheter heart valve in an all-comers population with severe aortic valve disease.
Monér Alchay, Davorka Lulic, Adel Aminian, Gintautas Bieliauskas, Yusuke Kobari, Pétur Pétursson, Ole De Backer, Oskar Angerås
Department of Molecular and Clinical Medicine, Institute of Medicine, University of Gothenburg, Gothenburg 413 45, Sweden. · The Heart Center, Rigshospitalet, Copenhagen, Denmark.
Key points
From the paper's conclusion- In the NAVICORE registry, the Navitor intra-annular TAVI system demonstrated high procedural success, favourable haemodynamics and low PVL rates supporting its use across a wide range of clinical and anatomical scenarios.
Abstract
BACKGROUND AND AIMS: The Navitor™ transcatheter aortic valve implantation (TAVI) system is a second-generation intra-annular self-expanding device featuring NaviSeal™ technology for paravalvular leak (PVL) prevention. Real-world data in diverse populations remain limited. We aimed to evaluate 30-day and 1-year outcomes of the Navitor TAVI system in a large all-comers population, including challenging anatomies traditionally associated with suboptimal results. METHODS AND RESULTS: This retrospective, multicenter registry (NAVICORE-NAVItor Collaborative Outcomes REgistry) included all consecutive patients (N = 736) undergoing TAVI with Navitor at three high-volume European centres between July 2021 and October 2024 (age: 80.2 ± 6.6 years, 47.2% female, 68.3% low surgical risk). Outcomes were assessed using Valve Academic Research Consortium-3 criteria. The technical success rate was 98.4%. The primary endpoint was a composite of all-cause mortality, disabling stroke, ≥moderate paravalvular leak (PVL), and valve re-intervention. Freedom from the primary endpoint at 30 days was 94.7%. At 12 months, freedom from death or disabling stroke was 89.3% and modified clinical efficacy was 81.1%. The mean transprosthetic gradient was 8.6 ± 4.9 mmHg at 1 year with an effective orifice area of 2.1 ± 0.5 cm2. More than moderate PVL occurred in 1.9% post-procedure and 1.6% at 12 months. In subgroup analyses, device success was 92.4% in severely calcified aortic stenosis, 87.1% in bicuspid valves, and 92.2% in small annuli <23 mm. Permanent pacemaker implantation was noted in 17.3% of pacemaker-naive patients. CONCLUSIONS: In the NAVICORE registry, the Navitor intra-annular TAVI system demonstrated high procedural success, favourable haemodynamics and low PVL rates supporting its use across a wide range of clinical and anatomical scenarios.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Outcomes and Valve Performance of Intra-Annular Self-Expanding Transcatheter Aortic Valve in Valve-in-Valve Procedures: Insights From the NAViV Registry.Journal of the American Heart Association · 2026
- Pooled Periprocedural and Short-Term Outcomes After Transcatheter Aortic Valve Replacement With Contemporary Self-Expanding Valves: A Systematic Review and Meta-Analysis.Structural heart : the journal of the Heart Team · 2026
- Transcatheter aortic valve-in-valve implantation for failed surgical aortic bioprostheses using the Navitor platform: early outcomes in a consecutive single-center cohort.Cardiology journal · 2026
- Five-Year Follow-Up of Transcatheter Aortic Valve Replacement With Self-Expanding Intra-Annular Versus Commercially Available Valves.JACC. Cardiovascular interventions · 2026
- One-Year Outcomes of Myval Versus Contemporary Transcatheter Heart Valves in Severe Aortic Stenosis: A Systematic Review and Meta-Analysis.Cardiology in review · 2026
- Clinical Outcomes of a Dedicated TAVR Device for Native Aortic Regurgitation: Insights From a Multicenter Real-World Experience.Circulation. Cardiovascular interventions · 2026