Combined imaging of myocardial scar and fat using artificial intelligence-guided dual bright- and black-blood late gadolinium enhancement.
Kalvin Narceau, Manuel Villegas-Martinez, Théo Richard, Victor de Villedon de Naide, Thaïs Génisson, Ewan Barel, Michel Haïssaguerre, Matthias Stuber,
IHU LIRYC, Heart Rhythm Disease Institute, Hôpital Xavier Arnozan, Université de Bordeaux-INSERM U1045, Avenue du Haut Lévêque, Pessac 33604, France.
Key points
From the paper's conclusion- Conclusion AI-guided SPOT-DIXON enables simultaneous, co-registered assessment of myocardial scar and fat within a single LGE acquisition.
Abstract
AIMS: Characterization of myocardial scar and fat is clinically important for diagnosis, risk stratification, and procedural planning in cardiomyopathies. While black-blood late gadolinium enhancement (LGE) improves scar conspicuity, fat remains hyperintense and may confound interpretation. We aimed to develop and evaluate SPOT-DIXON, a dual bright- and black-blood LGE sequence with Dixon water-fat separation and artificial intelligence (AI)-guided analysis, enabling simultaneous and co-registered quantification of myocardial scar and intra- and extra-cardiac fat. METHODS AND RESULTS: SPOT-DIXON alternates bright- and black-blood LGE preparations on consecutive heartbeats while acquiring dual-echo data for Dixon water-fat separation. Simulations, phantom experiments, and validations in a prospective cohort of 36 patients referred for cardiac magnetic resonance imaging were performed. An AI model automatically segmented the left ventricular (LV) wall on bright-blood water images, with contours propagation to scar and fat images. Simulations and phantoms confirmed preserved bright- and black-blood contrast and accurate water-fat separation. In patients, AI-based LV wall segmentation showed excellent agreement with manual delineation (global DICE = 84.4 ± 4.0%). SPOT-DIXON yielded higher scar volume, burden, and transmurality measurements than reference sequences, while LV wall volume was similar between sequences. Novel quantitative metrics, including intramyocardial fat burden expressed relative to scar mass, were feasible only with SPOT-DIXON. Acquisition times were comparable across sequences (5 min 55 s ± 2 min 17 s), while AI-based analysis substantially reduced post-processing time to 2.1 ± 0.7 s. CONCLUSION: AI-guided SPOT-DIXON enables simultaneous, co-registered assessment of myocardial scar and fat within a single LGE acquisition. This approach overcomes key limitations of current workflows and introduces novel quantitative markers of fibrofatty remodelling with potential clinical relevance in cardiomyopathies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-powered SPOT imaging for enhanced myocardial scar detection and quantificationNature Communications · 2025
- AI-Powered Detection of Left Ventricular Myocardial Scar from Dual-Sequence CT: Global and Segmental Prediction Validated by CMR.Journal of imaging informatics in medicine · 2026
- Artificial Intelligence-Derived Myocardial Fibrosis on Cardiac Magnetic Resonance for Prognosis in Cardiomyopathy: A Systematic Review of a Sparse Evidence Base.Current problems in cardiology · 2026
- Diagnostic efficacy of dual-energy coronary CT angiography for the identification of myocardial focal scarEuropean Heart Journal · 2026
- Magnetic resonance imaging-based quantitative assessment of fatty infiltration in skeletal muscle and myocardium: a narrative review of technical principles, differences in clinical applications, and future directions.Quantitative imaging in medicine and surgery · 2026
- False-Positive Scar Control in Scribble-Supervised LGE-CMR Segmentation Using an Asymmetric Intensity Prior.Journal of cardiovascular development and disease · 2026