Divergent aortic root cusp-to-cusp measurement techniques on CMR: geometric implications and threshold reclassification.
Jo M Zelis, Arie van Dijk, Toon D Duijnhouwer, Khibar Salah, Robin H Heijmen, Robin Nijveldt
Cardiology Department, Radboud University Medical Center, Nijmegen, The Netherlands. · Radiology Department, Radboud University Medical Center, Nijmegen, The Netherlands.
Key points
From the paper's conclusion- Cusp-to-cusp measurement techniques recommended by ESC and EACTS produce systematically divergent aortic root dimensions, resulting in significant patient reclassification across clinical thresholds. Although the middle measurement aligns more closely with the traced anatomical perimeter, the principal finding of this study is that guideline choice fundamentally alters patient categorization. Standardization of aortic root measurement conventions is essential to ensure consistent international care, improve research comparability, and reconcile historical risk thresholds with modern 3D imaging.
Abstract
OBJECTIVE: To evaluate discrepancies between current European guidelines (ESC vs. EACTS) regarding aortic root cusp-to-cusp measurements and assess their impact on risk stratification for prophylactic root replacement. METHODS AND RESULTS: A retrospective analysis was performed on a relative young cohort of 50 patients (mean age 42 years) who underwent non-contrast 3D cardiovascular magnetic resonance (CMR) imaging. We compared the widest-to-widest cusp measurements and the middle cusp-to-cusp measurements with each other and against a traced aortic root perimeter. The widest cusp-to-cusp measurement yielded systematically higher values compared to the middle measurement, showing a significant mean difference of 3.60 mm (P < 0.001). The middle measurement demonstrated better statistical agreement with the traced aortic root perimeter, achieving a Lin's Concordance Correlation Coefficient (CCC) of 0.98 and a Mean Absolute Error (MAE) of 3.96 mm. Conversely, widest cusp-to-cusp measurements exhibited substantially lower agreement (CCC 0.80) and significantly higher error rates (MAE 16.88 mm), consistently overestimating the perimeter. This led to the upward reclassification of 10.0% (5/50) and 16.0% (8/50) of patients across the 40 and 45 mm guideline thresholds, respectively. CONCLUSION: Cusp-to-cusp measurement techniques recommended by ESC and EACTS produce systematically divergent aortic root dimensions, resulting in significant patient reclassification across clinical thresholds. Although the middle measurement aligns more closely with the traced anatomical perimeter, the principal finding of this study is that guideline choice fundamentally alters patient categorization. Standardization of aortic root measurement conventions is essential to ensure consistent international care, improve research comparability, and reconcile historical risk thresholds with modern 3D imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Beyond Planar Measurements: Three‐Dimensional Geometry of the Normal Aortic Root, a CT Reference Framework for Valve SurgeryJournal of Cardiac Surgery · 2026
- Correlation Between Aortic Valve Area Measured by Cardiac Computed Tomography and Transthoracic Echocardiography in Patients with Aortic Stenosis.Journal of community hospital internal medicine perspectives · 2026
- Cardiovascular magnetic resonance reference ranges and centile-based categories for atrial and ventricular cardiac structure and function: 2026 Update from the Healthy Hearts ConsortiummedRxiv · 2026
- Cine Cardiac MRI Captures Cardiovascular Disease Risk Beyond Established Clinical Risk Factors: Evidence from the UK BiobankmedRxiv · 2026
- Beyond the two cusps: disparities in echocardiographic assessment and guideline adherence in bicuspid aortic valve management in ArgentinaEuropean Heart Journal · 2026
- Accuracy of CT-derived interarterial and intramural anomalous coronary arteries anatomy compared with 3D-reconstructed IVUS in-vivo reference.The international journal of cardiovascular imaging · 2026