Visual standardized quantification of late gadolinium enhancement, a contour-less method for late gadolinium enhancement quantification.
Giovanni Donato Aquaro, Roberto Licordari, Carmelo De Gori, Giancarlo Todiere, Umberto Ianni, Andrea Barison, Antonio De Luca, Alessandro Folgheraiter,
Department of Surgical, Medical and Molecular Pathology and of Critical Area, University of Pisa, Via Savi 10, 56126 Pisa, Italy. · Department of Clinical and Experimental Medicine, University of Messina, Messina, Italy.
Key points
From the paper's conclusion- VISTAQ provides highly reproducible, time-efficient LGE quantification without dedicated software and demonstrates non-inferior prognostic discrimination in HCM compared with conventional threshold-based techniques.
Abstract
AIMS: Late gadolinium enhancement (LGE) quantification by cardiovascular magnetic resonance is central to risk stratification in hypertrophic cardiomyopathy (HCM). Conventional techniques require contour tracing and region of interest (ROI) placement, which may reduce reproducibility and increase analysis time. We developed a novel visual approach, the visual standardized quantification (VISTAQ) of LGE, that does not require myocardial contouring, arbitrary ROI positioning, or dedicated post-processing software. METHODS AND RESULTS: LGE images from 400 patients (100 prior myocardial infarction, 250 HCM, and 50 other non-ischaemic heart diseases) were analysed. Reproducibility was assessed using the intra-class correlation coefficients (ICC) and Bland-Altman analysis. VISTAQ was compared with conventional methods [mean+2SD, +5SD, +6SD, full-width-at-half-maximum (FWHM), visual thresholding]. Prognostic performance was evaluated in 250 HCM patients. VISTAQ demonstrated excellent intra- and inter-observer reproducibility (ICC up to 0.98 and 0.97, respectively), consistent across disease subtypes. VISTAQ showed similar ICC to FWHM but significantly lower net and absolute inter-observer differences (median absolute difference: 1.3%). Mean+2SD markedly overestimated LGE, whereas mean+6SD slightly underestimated LGE compared with VISTAQ, mean+5SD, FWHM, and visual thresholding. Analysis time was shorter with VISTAQ (median 105 vs. 375 s, P < 0.0001). During follow-up, 21 hard cardiac events occurred in HCM population. An LGE threshold >10% predicted events with higher accuracy using VISTAQ [area under the curve (AUC): 0.90; sensitivity: 85%; specificity: 94%) compared with mean+6SD (AUC: 0.75; sensitivity: 57%; specificity: 93%). CONCLUSION: VISTAQ provides highly reproducible, time-efficient LGE quantification without dedicated software and demonstrates non-inferior prognostic discrimination in HCM compared with conventional threshold-based techniques.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enhancing risk prediction for sudden cardiac death: quantitative late gadolinium enhancement analysis in hypertrophic cardiomyopathy.Insights into imaging · 2026
- Prognostic significance of artificial intelligence-quantified late gadolinium enhancement on cardiac magnetic resonance in hypertrophic cardiomyopathy.The Korean journal of internal medicine · 2026
- A Visual LGE Extent Cutoff for Mortality Risk Stratification in Ischemic Cardiomyopathy.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2026
- Sex-related differences of late gadolinium enhancement granularity in hypertrophic cardiomyopathy: a cardiovascular magnetic resonance studyEuropean Heart Journal · 2026
- Simplified versus complete selvester QRS scoring system for scar assessment in hypertrophic cardiomyopathy patientsEuropean Heart Journal · 2026
- The diagnostic value of cardiovascular magnetic resonance in hypertrophic cardiomyopathyBMC Cardiovascular Disorders · 2026