Diagnostic value of positron emission tomography using amyloid-binding radiotracers for cardiac amyloidosis: a systematic review and meta-analysis.
Amely Walser, Konstantinos Bitos, Andreas A Giannopoulos, Aju P Pazhenkottil, Valerie Treyer, Martin W Huellner, Ronny R Buechel, Philipp A Kaufmann,
Departments of Nuclear Medicine and Cardiology, University Hospital Zurich, Ramistrasse 100, Zurich 8091, Switzerland.
Key points
From the paper's conclusion- Amyloid PET demonstrates high sensitivity and specificity for CA detection, even though the evidence base remains limited in terms of the number and scope of available studies. Prospective multicentre studies in consecutive patients with suspected CA are required to establish its clinical role and standardize acquisition protocols.
Abstract
AIMS: Amyloid-binding positron emission tomography (PET) tracers have emerged as a promising non-invasive tool for the diagnosis of cardiac amyloidosis (CA). This study aimed to assess the diagnostic accuracy of amyloid PET for detecting CA through a meta-analysis of diagnostic test accuracy. METHODS AND RESULTS: PubMed, Cochrane Library, Embase, and Web of Science were searched through 16 March 2026 for studies reporting the diagnostic performance of amyloid PET for CA. The primary analysis was a bivariate random-effects (Reitsma) model yielding summary sensitivity, specificity, the summary receiver operating characteristics curve with corresponding area under the curve (AUC), and positive and negative likelihood ratios. Subgroup analyses were performed by radiotracer and by amyloid subtype. Risk of bias was assessed using QUADAS-2 and publication bias by Deeks' funnel-plot asymmetry test. Twenty studies comprising 577 patients (407 with CA, 170 controls) met inclusion criteria, covering five radiotracers (11C-PiB, 18F-florbetaben, 18F-florbetapir, 18F-flutemetamol, and 124I-evuzamitide). In the primary bivariate model (k = 17), amyloid PET demonstrated a summary sensitivity of 0.91 (95% CI 0.83-0.96), specificity of 0.90 (95% CI 0.79-0.96), and AUC of 0.96, with low between-study heterogeneity (sensitivity I 2 = 13.4%; specificity I 2 = 0%). Sensitivity was high and consistent across 11C-PiB, 18F-florbetaben, 18F-florbetapir, and 124I-evuzamitide (0.96-1.00), with the exception of 18F-flutemetamol, which showed lower and heterogeneous sensitivity (0.70). CONCLUSION: Amyloid PET demonstrates high sensitivity and specificity for CA detection, even though the evidence base remains limited in terms of the number and scope of available studies. Prospective multicentre studies in consecutive patients with suspected CA are required to establish its clinical role and standardize acquisition protocols.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 124Iodine Evuzamitide Positron Emission Tomography in Patients with Established or Suspected Cardiac Amyloidosis.JACC. Cardiovascular imaging · 2026
- Imaging the invisible: comparative diagnostic accuracy of cardiac imaging techniques for amyloidosisEuropean Heart Journal · 2026
- 124I-Evuzamitide Positron Emission Tomography/Computed Tomography for Diagnosing Cardiac Amyloidosis: The REVEAL Nonrandomized Clinical Trial.JAMA · 2026
- Diagnostic Sensitivity of [18F]-Florbetaben-PET/CT in Detecting Cardiac Involvement in AL Amyloidosis: The Prospective MoRBiDA Study.JACC. Advances · 2026
- Amyloid-targeted PET after negative or low-grade bone scintigraphy for cardiac amyloidosis: a systematic review.The international journal of cardiovascular imaging · 2026
- Pittsburgh compound B positron emission tomography detects cardiomyopathy in hereditary transthyretin amyloidosis patients with negative bone scintigraphy: a pilot studyFrontiers in Nuclear Medicine · 2026