Successful termination of ventricular tachycardia by intrinsic antitachycardia pacing delivered from a left bundle branch area pacing lead: a case report.
Noriaki Moriyama, Yoichi Sugiyama, Yohei Hiruma, Kunihiko Shimizu, Shigeru Saito
Department of Cardiology, Shonan Kamakura General Hospital, 1370-1 Kamakura Okamoto, Kamakura 2478533, Japan.
Key points
From the paper's conclusion- We report a 57-year-old man with advanced heart failure who underwent implantation of LBB-optimized cardiac resynchronization therapy with defibrillator for secondary prevention.
Abstract
BACKGROUND: Intrinsic antitachycardia pacing (iATP) is an advanced algorithm designed to optimize pacing sequences for ventricular tachycardia (VT) termination. Although left bundle branch area pacing (LBBAP) has emerged as a physiological pacing strategy and is increasingly incorporated into cardiac resynchronization therapy, its role as a delivery site for iATP remains unclear. CASE SUMMARY: We report a 57-year-old man with advanced heart failure who underwent implantation of LBB-optimized cardiac resynchronization therapy with defibrillator for secondary prevention. During follow-up, multiple episodes of sustained VT with different morphologies were consistently and successfully terminated by iATP delivered exclusively from the LBBAP lead, without the need for conventional ATP or shock therapies. DISCUSSION: This case suggests that conduction system pacing via the LBB area may provide a novel and effective substrate for antitachycardia pacing, potentially enabling more rapid engagement of re-entrant circuits through the His-Purkinje system. Further studies are warranted to establish the efficacy of iATP delivered from conduction system pacing leads.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intrinsic versus conventional antitachycardia pacing for ventricular tachycardia: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Permanent LEft ventricular septAl Pacing vs. right ventricular pacing in patients with atrioventricular conduction disorders-a randomized trial: rationale and design of the LEAP trial.European heart journal open · 2026
- Left ventricular endocardial pacing via controlled interventricular septal lead passage as bailout after failed left bundle branch area pacing optimized CRTEuropean Heart Journal · 2026
- Left bundle branch area pacing induced dual bundle branches non-reentrant bigeminy and Takotsubo cardiomyopathy: a case report.Frontiers in physiology · 2026
- Leadless Atrial Pacing Targeting Bachmann Bundle for Atrial Resynchronization: A Single Center Registry.Heart rhythm · 2026
- Tailoring the Atrioventricular Interval During Left Bundle Branch Pacing: Playing With Fusion.Pacing and clinical electrophysiology : PACE · 2026