The Fabulous® stent system facilitates complete false lumen remodelling mainly with bare stent components in treating acute Stanford type B aortic dissection: a case report.
Shouji Qiu, Weiguo Fu, Lixin Wang
Department of Vascular Surgery, Zhongshan Hospital, Fudan University, 180 Fenglin Road, Shanghai 200032, China.
Key points
From the paper's conclusion- This integrally designed stent system of combining a self-expanding, anti-compression bare stent with a covered stent graft effectively addresses the issue of acute type B aortic dissection with a severely compressed true lumen of the visceral aortic segment.
Abstract
BACKGROUND: Stanford type B aortic dissection typically involves the distal part of the aorta, with covering the proximal tear being sufficient for treatment in the majority of these patients. The real challenge arises in cases with severely compressed true lumen, where implanting only the proximal stent-graft is insufficient to dilate the visceral segment of the aorta and the distal true lumen. CASE SUMMARY: A 58-year-old male patient was admitted to our centre due to acute type B aortic dissection for 3 days. Contrast-enhanced computed tomography angiography (CTA) revealed the dissection had continuously extended downward to the right iliac artery, and the true lumen of the distal aorta was compressed close to occlusion at the visceral artery level. The Fabulous® stent system was applied in this case, with a covered stent sealing the proximal entry, and two self-expanding, anti-compression bare stents expanding the true lumen. Postoperative CTA showed satisfactory aortic remodelling, with the true lumen fully opening and the false lumen completely disappearing. DISCUSSION: This integrally designed stent system of combining a self-expanding, anti-compression bare stent with a covered stent graft effectively addresses the issue of acute type B aortic dissection with a severely compressed true lumen of the visceral aortic segment. By utilizing modularized bare stents with an appropriate mesh diameter to expand the distal aorta, it sufficiently promotes aortic remodelling. At the same time, the stent system provides adequate branch arterial blood flow, effectively reducing the risk of severe complications such as paraplegia and renal failure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Initial Surgical Experience of a Novel Frozen Elephant Trunk Without Distal Stent for Acute Type A Aortic Dissection.Annals of thoracic surgery short reports · 2026
- From stent to stability: Conservative management of post-stenting aortic dissection in coarctation of the aorta.Annals of pediatric cardiology · 2026
- Emergent Total Endovascular Repair Using Retrograde in Situ Branched Stent Grafting for Ruptured Retrograde Aortic Dissection.Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia · 2026
- Case Report: Endovascular repair for true lumen collapse after frozen elephant trunk for type A aortic dissection.Frontiers in cardiovascular medicine · 2026
- Early Staged STABILISE Technique Achieves Favorable Aortic Remodeling after Central Repair for Acute Type A Aortic Dissection.Annals of vascular diseases · 2026
- A Branch-Specific Combined Fenestration Strategy for Chronic Aortic Dissection With Severe Paravisceral True Lumen Compression.Journal of vascular and interventional radiology : JVIR · 2026