First use of pulsed field ablation in a patient with a deep brain stimulator: a case report.
Alexandra Marx, David Schaack, K R Julian Chun, Boris Schmidt, Lukas Urbanek
Cardioangiologisches Centrum Bethanien, Agaplesion Markus-Krankenhaus, Wilhelm-Epstein- Str. 4, Frankfurt/M 60431, Germany.
Key points
From the paper's conclusion- These findings suggest that, with appropriate precautions, PFA may represent a viable ablation strategy in selected patients with implanted neurostimulation systems.
Abstract
BACKGROUND: Pulmonary vein isolation for atrial fibrillation (AF) in patients with implanted neurostimulation devices is challenging, as established energy sources, such as radiofrequency (RF) ablation, are generally not recommended in these patients due to the risk of device interference. Pulsed field ablation (PFA) for AF offers relative myocardial selectivity and a potentially improved safety profile. However, data on its use in patients with implanted neurostimulation devices are lacking. CASE SUMMARY: A 66-year-old woman with paroxysmal AF was referred to our centre for catheter ablation. Years earlier, a deep brain stimulator (DBS) had been implanted to control severe fasciculations. As RF ablation is not recommended in such patients and given the patient's multiple comorbidities, a single-shot ablation strategy was chosen. After selective pulmonary vein angiography revealed a large left common pulmonary vein (LCPV), PFA using a pentaspline catheter was selected, as this approach allows effective treatment of a LCPV with short procedure times and a favourable safety profile. The DBS was deactivated prior to the procedure and ablation was performed without complications. After the procedure, the DBS was reactivated and showed no evidence of device malfunction. DISCUSSION: This is the first reported case that demonstrates the feasibility of PFA in a patient with an implanted DBS. Temporary deactivation of the neurostimulation device and careful multidisciplinary planning allowed successful ablation without device dysfunction or interference. These findings suggest that, with appropriate precautions, PFA may represent a viable ablation strategy in selected patients with implanted neurostimulation systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pulsed Field Ablation in Patients With Cardiac Implantable Electric Devices: Vigilance Is WarrantedPacing and Clinical Electrophysiology · 2025
- Context-dependent interactions between variable-loop pulsed field ablation and cardiac implantable electronic devices: a controlled preclinical study.European heart journal open · 2026
- Pulsed Field Ablation for Atrial Fibrillation: Mechanism, Clinical Evidence, and Emerging Applications.Cureus · 2026
- Treatment of paroxysmal and persistent atrial fibrillation with pulsed field ablation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Practical Guide on the Use of the PulseSelect Pulsed Field Ablation System for Atrial Fibrillation Ablation Procedures.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Complications of pulsed-field ablation for atrial fibrillation: a narrative structured review.Frontiers in cardiovascular medicine · 2026