Tricuspid inflow E-wave velocity for the assessment of severe or greater tricuspid regurgitation: derivation and external validation of threshold values.
Samantha Fisicaro, Madalina-Patricia Moldovan, Yuka Kawada, Marco Penso, Matheus Simonato, Alexandra Simona Buta, Andra Negru, Alexandra Clement,
Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy. · Columbia University Irving Medical Center and Cardiovascular Research Foundation, New York, NY, United States.
Key points
From the paper's conclusion- The guideline-recommended threshold of >100 cm/s is highly insensitive for detecting severe or greater TR. Lower cut-offs, particularly 47 cm/s, may be useful for screening to trigger a comprehensive multiparametric assessment.
Abstract
AIMS: Current guidelines include tricuspid inflow E-wave (>100 cm/s by pulsed-wave Doppler) as a semiquantitative criterion for diagnosing severe tricuspid regurgitation (TR), despite limited supporting evidence. We assessed its diagnostic performance for identifying severe or greater TR, deriving and externally validating practical thresholds. METHODS AND RESULTS: Tricuspid inflow E-wave velocity was measured by pulsed-wave Doppler in consecutive patients with at least mild TR between December 2024 and February 2026. Among 178 patients (77±13 years, 65% women), TR was mild in 44, moderate in 61, severe in 44, massive in 15, and torrential in 14. Mean tricuspid E-wave velocity was 56±16 cm/s and increased with TR severity: 47±8, 50±10, 62±16, 67±13, and 77±21 cm/s for mild, moderate, severe, massive, and torrential TR. Only three patients had E-wave velocity >100 cm/s (one with severe and two with torrential TR). Using multiparametric echocardiographic grading as the reference standard, the >100 cm/s threshold showed 5.5% sensitivity, 100% specificity, and kappa 0.25 for severe or greater TR. As a continuous variable, E-wave velocity discriminated severe or greater TR with an AUC of 0.81. A lower threshold of 52 cm/s yielded 81% sensitivity and 67% specificity, whereas 47 cm/s provided 90% sensitivity and 43% specificity. External validation resulted in 94% sensitivity and 47% specificity. CONCLUSION: The guideline-recommended threshold of >100 cm/s is highly insensitive for detecting severe or greater TR. Lower cut-offs, particularly 47 cm/s, may be useful for screening to trigger a comprehensive multiparametric assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Refining tricuspid regurgitation severity assessment with new corrected proximal isovelocity surface area threshold valuesEuropean Heart Journal - Cardiovascular Imaging · 2025
- Prognostic Thresholds of Tricuspid Regurgitation in Transthyretin Amyloid Cardiomyopathy.JAMA cardiology · 2026
- Hemodynamic phenotypes and clinical outcomes in patients with severe tricuspid regurgitationEuropean Heart Journal · 2026
- Cardiac index refines risk stratification in tricuspid regurgitation beyond valve severityEuropean Heart Journal · 2026
- Redefining the assessment of secondary tricuspid regurgitation based on novel 3D parameters: an echocardiographic approach to risk stratificationEuropean Heart Journal · 2026
- Quantitative tricuspid regurgitation assessment by cardiac magnetic resonance: novel insightsEuropean Heart Journal - Cardiovascular Imaging · 2025