Journal of Crohn's & colitis

Value of non-contrast magnetic resonance imaging for diagnosis of perianal fistulas in Crohn's disease.

Sara Lewis, Amandeep Ahluwalia, Dimitra Landis, Emre Altinmakas, Andrew Kirsner, Ryan Yu, John Doucette, Serre-Yu Wong,

Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, United States. · Environmental Medicine and Climate Science, Icahn School of Medicine at Mount Sinai, New York, NY, United States.

Key points

From the paper's conclusion
  • NC-MRI has high agreement with CE-MRI for index perianal fistula and abscess detection with clinical feasibility in CD patients. CE-MRI had added value for assessment of complex PFCD, including secondary fistulas and tracts.

Abstract

PURPOSE: To compare non-contrast (NC)-MRI and contrast-enhanced (CE)-T1-weighted imaging (T1-WI) for the detection and characterization of perianal fistulizing Crohn's disease (PFCD). METHODS: This Institutional Review Board-approved retrospective study included patients with Crohn's disease (CD) who underwent pelvic MRI (T2-WI, diffusion-weighted imaging [DWI], pre and post-contrast T1-WI) from 10/2021 to 12/2022. Two independent observers assessed presence and severity of perianal disease (St. James Criteria) and abscesses (presence/size) in 2 separate sessions: NC-MRI (T2-WI, DWI, pre-contrast-T1-WI) and CE-MRI (NC-MRI + post-contrast-T1-WI) separated by 6 weeks. Agreement between modalities was evaluated using weighted Cohen's kappa. Performance of NC-MRI was assessed against CE-MRI as the reference standard. RESULTS: One hundred and forty-five patients (M/F 92/53, mean age 36.2 ± 15.1 years) were included. On NC-MRI, an index fistula was detected in 115/145 patients (grade 1 [n = 55]/grade 2 [n = 15]/grade 3 [n = 16]/grade 4 [n = 33]/grade 5 [n = 6]). On CE-MRI, an index fistula was detected in 117/145 patients (grade 1 [n = 36]/grade 2 [n = 39]/grade 3 [n = 8]/grade 4 [n = 29]/grade 5 [n = 5]). An abscess was detected on NC-MRI in 53 patients (37%) (mean size = 3.3 cm) and on CE-MRI in 63 patients (43%) (mean size = 3.0 cm). There was fair-to-substantial agreement between NC-MRI and CE-MRI (range, 0.46 [presence of secondary tracts] to 0.87 [presence of index fistula]), except for secondary fistula length (no agreement, kappa = 0.008). Compared to CE-MRI, NC-MRI demonstrated a sensitivity/specificity/PPV/NPV/accuracy of 0.96/0.93/0.98/0.84/0.95 for index fistula detection and 0.77/0.95/0.92/0/84/0.87 for abscess detection. CONCLUSIONS: NC-MRI has high agreement with CE-MRI for index perianal fistula and abscess detection with clinical feasibility in CD patients. CE-MRI had added value for assessment of complex PFCD, including secondary fistulas and tracts. CLINICAL RELEVANCE: NC-MRI had high agreement with CE-MRI for detecting perianal fistulas and substantial agreement for grading. CE-MRI has added value in diagnosing complex perianal disease. NC-MRI of the pelvis is a reasonable alternative for perianal fistula detection and grading for patients who cannot receive contrast or for potentially abbreviated exams.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Value of non-contrast magnetic resonance imaging for diagnosis of perianal fistulas in Crohn's disease — Science Skim