Intraoperative impedance planimetry for assessment of pyloric function in minimally invasive esophagectomy.
Jarlath C Bolger, Frances Allison, Elliot Wakeam, Jonathan C Yeung
Department of Surgery, Royal College of Surgeons in Ireland, Education and Research Centre, Beaumont Hospital, Dublin 9, Ireland. · Division of Thoracic Surgery, University Health Network, Toronto, Ontario, Canada.
Key points
From the paper's conclusion- Several lessons emerged: intraoperative pyloric impedance planimetry is feasible when intraoperative endoscopy is already part of routine workflow.
Abstract
Pyloric management during esophagectomy remains controversial. Routine drainage may improve conduit emptying in some patients but exposes others to potential long-term symptoms including dumping syndrome and bile reflux. Conversely, omission of drainage avoids routine intervention but leaves a subset of patients requiring postoperative endoscopic treatment for delayed gastric emptying. The central problem is the lack of a validated method to identify, at the time of operation, which patients are likely to benefit from pyloric intervention. We describe early lessons from incorporating intraoperative impedance planimetry using EndoFLIP into minimally invasive esophagectomy. The assessment was performed as an incremental addition to routine on-table endoscopy after gastric conduit reconstruction. In 20 consecutive patients, pyloric distensibility index and diameter were measured at 30, 40, and 50 mL balloon fill volumes. Assessment was completed in all patients, added less than 10 minutes to operative time, and caused no device-related complications. Nine patients subsequently underwent postoperative pyloric dilation, most commonly for symptomatic delayed gastric emptying. These patients had lower intraoperative pyloric distensibility at 40 and 50 mL, whereas pyloric diameter did not differ between groups. Several lessons emerged: intraoperative pyloric impedance planimetry is feasible when intraoperative endoscopy is already part of routine workflow. Distensibility appears more informative than static diameter. Higher balloon fill volumes may better reveal clinically relevant differences. Finally, postoperative dilation is a pragmatic but imperfect endpoint because it is partly influenced by surgeon judgment and institutional practice. These observations support further prospective evaluation of intraoperative pyloric distensibility as a potential basis for selective, physiology-guided pyloric management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prophylactic pyloric drainage for prevention of delayed gastric conduit emptying following Ivor Lewis esophagectomy: a systematic review with exploratory synthesisSurgical Endoscopy · 2026
- Practical Application of EndoFLIP in the Evaluation of Patients with Dysphagia.Diagnostics (Basel, Switzerland) · 2026
- Interactive Panometry: Using Proximal Balloon Distension During Functional Lumen Imaging Probe Panometry to Enhance Motility Evaluation of Inhibitory Function.Journal of neurogastroenterology and motility · 2026
- Role of Functional Luminal Imaging Probe in the Evaluation and Management of Pediatric Esophageal Disorders.Children (Basel, Switzerland) · 2026
- Functional Lumen Imaging Probe (EndoFLIP) in Upper Gastrointestinal Disorders: Current Evidence, Clinical Applications, and Future Perspectives.Diseases (Basel, Switzerland) · 2026
- Contemporary international practice patterns in the prevention, diagnosis, and management of delayed gastric conduit emptying after oesophagectomy: an international survey of oesophagogastric surgeons.Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus · 2026