科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ International journal of implant dentistry2026-08-19

Accuracy of CBCT and dental-MRI for detecting peri-implant bone defects at single titanium implants: an in-vitro pilot study.

Katharina Hartung, Nikolai Miotk, Arne Lauer, Franz Sebastian Schwindling, Mathias Nittka, Ali Özen, Ute Ludwig, Jan-Bernd Hövener, Michael Bock, Tabea Flügge, Anne-Katrin Eisenbeiss, Peter Rammelsberg, Sabine Heiland, Martin Bendszus, Tim Hilgenfeld

一句话结论 · In one sentence

Under optimized ex vivo conditions, dMRI offers a promising reliability and accuracy for identifying and classifying peri-implant bone defects around single titanium implants. High-resolution dMRI facilitates radiation-free, three-dimensional peri-implant tissue visualization.

原始摘要(英文原文)· Original abstract
PURPOSE: To evaluate the reliability and accuracy of optimized dental-MRI (dMRI) for detecting and classifying peri-implant bone defects around single titanium implants. METHODS: 48 titanium implants were inserted into bovine ribs. 24 implants had surrounding standardized defects (1-wall, 2-wall, 3-wall, 4-wall) in two sizes (1 mm and 3 mm), while the other 24 implants showed no peri-implant bone defects. CBCT and dMRI were performed and analyzed twice by two readers. 3 Tesla MRI was conducted using an innovative intraoral coil and a novel, T1-weighted sequence for metal artifact reduction (CS-SEMAC). Cohen's Kappa (κ), sensitivity, and specificity were assessed for bone defect detection, size, and type. Modality differences were evaluated using the exact McNemar test and Firth penalized-likelihood logistic regression. RESULTS: For bone defect detection, almost perfect intra-/inter-rater reliability (κ-value range: 0.958-1) was found for both imaging modalities, with high sensitivity/specificity (CBCT 100%/100%, 95% CI 0.962-1.000/0.962-1.000; MRI 98%/100%, 95% CI 0.927-0.998/0.962-1.000), confirmed by Firth regression (p = 0.22). For defect type classification, both CBCT (κ-value range: 0.884-0.913) and MRI (κ-value range: 0.794-0.942) demonstrated almost perfect intra-/inter-rater reliability. Overall sensitivity/ specificity were 86%/99% (95% CI 0.780-0.926 and 0.985-0.995) for CBCT and 84%/99% (95% CI 0.755-0.910 and 0.985-0.995) for dMRI, with no significant difference between modalities (Firth-adjusted OR 0.85, 95% CI 0.38-1.88, p = 0.68). CONCLUSIONS: Under optimized ex vivo conditions, dMRI offers a promising reliability and accuracy for identifying and classifying peri-implant bone defects around single titanium implants. High-resolution dMRI facilitates radiation-free, three-dimensional peri-implant tissue visualization.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Accuracy of CBCT and dental-MRI for detecting peri-implant bone defects at single titanium implants: an in-vitro pilot study. — 科研速览 Science Skim