Clinical chemistry

Fragment End Motif Analysis of Microbial Cell-Free DNA Improves Detection of Pathogens over Noise from Contaminants and Commensals.

Haikun Zhang, Eddie G Dominguez, Mary Junak, Kate V Lauer, Nicole L Werner, Muhammed Murtaza, Caitlin S Pepperell, Mehreen T Kisat

Center for Precision Medicine, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, United States. · Department of Surgery, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, United States.

Key points

From the paper's conclusion
  • mDNA end motif analysis improves signal-to-noise ratio beyond microbial abundance alone and improves pathogen detection in plasma metagenomic sequencing.

Abstract

BACKGROUND: Circulating plasma microbial DNA (mDNA) is a promising biomarker for sepsis, but its accuracy is hindered by the low abundance of pathogen DNA and the presence of contaminants and commensals. mDNA enrichment using a selection of short fragments and single-stranded DNA (ssDNA) library preparation can improve pathogen yield but also increases background noise. Since nucleotide representation at mDNA fragment ends is biased by enzymatic digestion in vivo, we hypothesized that analysis of 5' and 3' mDNA fragment end motifs in enriched ssDNA libraries could improve pathogen detection. METHODS: We performed deep metagenomic sequencing of size-selected ssDNA libraries from 38 plasma samples, including 20 samples from 5 sepsis patients, 18 samples from 6 patients without infection, and 6 no-template controls. Across these samples, we compared observed-to-expected ratios for end motifs in mDNA fragments from candidate pathogens and contaminants. For each candidate pathogen, we evaluated the accuracy of combining end motifs with microbial abundance for detection of infection. RESULTS: mDNA fragments from infection-causing pathogens were biased in the nucleotide motifs at both fragment ends compared with contaminants, with the highest enrichment observed in the GG dinucleotide at the 3' end (P < 0.0001). Integrating microbial abundance with end motif features improved differentiation between clinically significant pathogens and corresponding noise from the same microbes in noninfection samples. For Staphylococcus infections, area under the receiver operating characteristic curve for the combination model was higher than than that for microbial abundance alone (0.892 vs 0.431, respectively; P = 0.018). CONCLUSIONS: mDNA end motif analysis improves signal-to-noise ratio beyond microbial abundance alone and improves pathogen detection in plasma metagenomic sequencing.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers