Clinical Chemistry

B-384 Hydrolysis of Clinical Urine Specimens for Monitoring Nicotine Use

Taylor Hunt, Dustin Sill, Michael Smith, Sarah Bartock

Key points

From the paper's conclusion
  • Conclusion We demonstrated that hydrolysis of urine specimens is an important sample preparation step for more accurately assessing nicotine use.

Abstract

Background Estimating the dose and possible route of exposure to tobacco or nicotine products in urine requires measurement of nicotine, its primary metabolites, and anabasine. The presence of anabasine reflects tobacco use rather than nicotine replacement therapies (NRTs). Nicotine undergoes extensive metabolism by cytochrome P450 in the liver, mainly to cotinine and trans-3’-hydroxycotinine. These metabolites also undergo glucuronidation by UDP-glucuronyltransferase (UGT) to form cotinine glucuronide and trans-3’-hydroxycotinine glucuronide. Variations in enzyme activity of individuals can lead to different concentrations of metabolites and conjugated metabolites. In contrast, anabasine is typically found in its free form. The objective of the current study was to assess whether hydrolysis of urine specimens can result in a more accurate measurement of nicotine intake without monitoring the conjugated forms of the analytes. Methods In total, 44 patient urine specimen discards were de-identified and used for this study, 21 with negative and 23 with positive results on previous nicotine screening. Hydrolysis was performed using B-One enzyme (Kura Biotech, Los Angeles, CA) diluted for 30 minutes at room temperature with a 15% methanol solution. Hydrolysis efficiency was 97% based on B-One enzyme hydrolysis of cotinine N-beta-D-glucuronide at a target concentration of 800 ng/mL under the same conditions. LC-MS/MS was performed using a high-throughput method previously validated per ANSI/ASB standards. The nicotine, cotinine, and anabasine analytical measuring range (AMR) was 2 ng/mL to 1,000 ng/mL and the trans-3’-hydroxycotinine AMR was 25 ng/mL to 1,000 ng/mL. Measured values were compared with, and without, hydrolysis. Results that were above the AMR of the assay before hydrolysis were excluded. Results Specimens that initially tested negative for nicotine, and trans-3’-hydroxycotinine remained negative with hydrolysis. For specimens that tested positive, hydrolysis related changes ranged from 0% to 203%, with the average percent change for nicotine, 49% (n=20, range 2-847 ng/mL); cotinine, 109% (n=19, range 11-934 ng/mL); and trans-3’-hydroxycotinine, 24% (n=14, range 62-804 ng/mL). Within these specimens, only 6 of 23 (26%) contained anabasine, for which values were unchanged with hydrolysis. Conclusion We demonstrated that hydrolysis of urine specimens is an important sample preparation step for more accurately assessing nicotine use. Higher levels of nicotine and its metabolites were detected with hydrolysis, with variability reflecting differences in patient metabolism of conjugated and unconjugated forms due to varying activity rates of UGT. As expected, hydrolysis had no effect on specimens that previously tested negative, nor on the detected levels of anabasine. The presence of anabasine only in about one quarter of specimens may reflect the downward trend in tobacco smoking rates and increased intake of alternative nicotine sources like patches, vapes, pouches, and alternative NRTs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

B-384 Hydrolysis of Clinical Urine Specimens for Monitoring Nicotine Use — Science Skim