B-352 Selective phospholipid enrichment strategy for evaporation-free, automatable phosphatidylethanol extraction from whole blood for liquid chromatography-tandem mass spectrometry
Sarrah Lahorewala, Jacob Nielsen, Qingwen Yang, Hai Huynh, Yiwei Liu, Xin Yi
Key points
From the paper's conclusion- These data indicate that controlled hydration is essential for effective disruption of the phosphate headgroup-sorbent interactions that allow analyte release while maintaining solubility.
Abstract
Background Phosphatidylethanols (PEth) are highly sensitive and specific biomarkers of alcohol consumption increasingly used for objective assessment of recent and longitudinal alcohol exposure. Development of liquid chromatography-tandem mass spectrometry (LC–MS/MS) methods for PEth is challenging because whole blood is a complex matrix and PEth itself is a phospholipid, a class typically removed during sample preparation due to ion suppression and background interference. This study aimed to develop a simple, automatable extraction strategy that repurposes phospholipid removal systems to selectively retain PEth while minimizing matrix effects. Methods To determine the optimal extraction strategy, PEth 16:0/18:1 and PEth 16:0/18:2 were spiked into whole blood and evaluated using protein precipitation alone or precipitation followed by phospholipid retention on a zirconia-based phospholipid removal cartridge operated in reverse. Precipitation conditions included isopropanol (IPA) or 1:1 IPA–acetonitrile (ACN), with or without evaporation and reconstitution. For phospholipid retention workflows, precipitation with ACN or 1:1 IPA–ACN was followed by cartridge washing and elution with IPA containing 1% ammonium hydroxide (NH4OH) with varying aqueous content (100%, 90%, or 80% IPA). Recovery, background signal, peak morphology, and ion suppression were assessed to determine optimal extraction conditions. Results Protein precipitation-only approaches were insufficient for robust PEth extraction. Simple isopropanol (IPA) precipitation produced low recovery, broad peaks, and significant ion suppression, indicating inadequate matrix cleanup. Addition of acetonitrile (ACN) improved peak shape and reduced baseline noise but introduced co-elution that precluded reliable quantification. In contrast, phospholipid retention cartridges successfully captured and retained PEth from the matrix. Elution efficiency was strongly dependent on solvent composition. Pure organic solvent (100% IPA + 1% NH4OH) produced clean background yet incomplete PEth release. Introducing 10% water (90% IPA + 1% NH4OH) increased recovery by >50% without increasing interference, whereas increasing hydration to 20% abolished PEth detection. These data indicate that controlled hydration is essential for effective disruption of the phosphate headgroup-sorbent interactions that allow analyte release while maintaining solubility. The final method, 1:1 IPA–ACN precipitation followed by phospholipid retention and elution with 90% IPA + 1% NH4OH, yielded minimal interference and approximately twofold higher recovery than precipitation-only approaches, without requiring evaporation. Chromatographic separation was achieved using a phenyl-hexyl column with a total LC run time of 3.5 minutes. Mass spectrometric detection was performed in negative electrospray ionization mode using multiple reaction monitoring, with transitions selected based on signal-to-noise performance to enhance specificity. The optimized LC–MS/MS assay demonstrated linearity from 10–1000 ng/mL for both PEth species (R² = 0.99). Limits of blank, detection, and quantification were 0.8/2.0/6.4 ng/mL for PEth 16:0/18:1 and 1.4/3.2/8.1 ng/mL for PEth 16:0/18:2. Coefficients of variation for within-run precision were <5% for 16:0/18:1 and <10% for 16:0/18:2, and for between-run precision were <8.8% and <11.7%, respectively. Conclusion These results support a sensitive, precise, evaporation-free extraction workflow suitable for automated, high-throughput clinical implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-390 Phosphatidylethanol (PEth) 16/18.1 and 16/18.2 quantification in whole blood and dried blood spotsClinical Chemistry · 2026
- Integrated internal standard volumetric dried blood microsampling for the quantification of phosphatidylethanol 16:0/18:1.Analytical and bioanalytical chemistry · 2026
- Systematic Study on Phosphatidylethanol (PEth) Stability and De Novo Formation in Authentic Whole Blood Samples.Drug testing and analysis · 2026
- B-400 Phosphatidylethanol as an Objective Alcohol Biomarker Informing Liver Transplant Candidacy and Post-Transplant OutcomesClinical Chemistry · 2026
- Integrating Phosphatidylethanol to Enhance Alcohol Quantification in Steatotic Liver Disease and Clinical TrialsLiver International · 2025
- Self-collected dried blood spots for phosphatidylethanol assessment in virtual trials: Feasibility and concordance with self-reported alcohol use among men at high HIV risk.Research square · 2026