Clinical Chemistry

B-297 Ceftazidime induces method-dependent underestimation of serum albumin: a clinically observed drug–assay interaction

Harue Suzuki, Yoko Usami, Shixing Wu, Akari Yamamoto, Satoshi Fujimura, Riho Shimizu, Nau Ishimine

Key points

From the paper's conclusion
  • Conclusion Ceftazidime reduces serum albumin concentrations measured by the modified BCP method in a method-dependent manner, without affecting BCG measurement or electrophoretic quantification.

Abstract

Background During routine serum protein electrophoresis (SPE), we observed an unusual albumin band which was broad and shifted toward a cathode in a patient. This electrophoretic pattern resembled previously reported findings during high-dose penicillin G therapy. The patient had been receiving ceftazidime for treatment of bacterial infection. High-dose penicillin G is known to cause underestimation of serum albumin concentrations when measured by the modified bromocresol purple (BCP) method; however, the effect of other ß-lactam antibiotics has not been well characterized. We investigated whether ceftazidime affects albumin measurement and electrophoretic patterns using both clinical data and in vitro experiments. Methods Serum albumin concentrations in the patient were compared using the bromocresol green (BCG) method, the modified BCP method, and SPE during and after ceftazidime therapy. For in vitro evaluation, pooled serum was supplemented with ceftazidime at final concentrations of 0–800 mg/L and incubated at 37°C for up to 168 hours. Albumin concentrations were measured at each time point using BCG and modified BCP methods. SPE was also performed after incubation. Results The patient received ceftazidime for 17 days. On day 4 of therapy, albumin concentrations were 25.6 g/L by BCG, 20.7 g/L by modified BCP, and 26.7 g/L by SPE. On day 14 of therapy, corresponding values were 28.5 g/L, 24.3 g/L, and 29.9 g/L, respectively. The modified BCP method consistently yielded values approximately 15–20% lower than those obtained by BCG and SPE. In vitro, albumin concentrations measured by the modified BCP method decreased in a concentration- and time-dependent manner. At the highest concentration (800 mg/L), values decreased to approximately 80% of control after 72 hours of incubation. In contrast, albumin values measured by the BCG method and SPE showed no significant changes. The reported peak plasma concentration of ceftazidime is approximately 200 mg/L. At concentrations near this level, in vitro reductions in albumin measured by modified BCP were limited. Conclusion Ceftazidime reduces serum albumin concentrations measured by the modified BCP method in a method-dependent manner, without affecting BCG measurement or electrophoretic quantification. The magnitude of albumin reduction observed in the patient could not be fully explained by simple concentration-dependent effects observed in vitro. Time-dependent albumin modification related to the ß-lactam structure or in vivo environmental factors may contribute to this discrepancy. These findings highlight a clinically relevant drug–assay interaction. Laboratory professionals and clinicians should recognize that albumin concentrations measured by the modified BCP method may be underestimated in patients receiving ß-lactam antibiotics.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers