B-263 Improving Critical Value Communication Using Epic Closed Loop Electronic Notification
Carlos Vasquez, Angela Lauster, David Ramos
Key points
From the paper's conclusion- Conclusion The implementation of the EMR integrated closed loop communication system significantly improved the efficiency, timeliness, and standardization of inpatient critical value notification at TGH while reducing manual laboratory workload.
Abstract
Background Communication of critical laboratory values is a laboratory responsibility and is essential for patient care. Conventional systems using phone call notification are labor-intensive, workflow disruptive, often create delays, and are prone to communication errors. Closed loop electronic communication integrated within the electronic medical record (EMR) offers an opportunity to standardize the process and improve timely notification. The objective of this study was to evaluate the operational performance and impact of a closed loop electronic communication system implemented for inpatient critical laboratory value notification at a large Academic Medical Center. Methods A new closed loop electronic communication system was implemented at Tampa General Hospital (TGH - Tampa, FL) to support notification of critical laboratory values. The new system delivers critical results electronically to the care team and requires acknowledgment within 10 minutes, with date and time documented in the EMR to close the communication loop. If communication isn't closed electronically by nursing, the result changes color on the Medical Laboratory Scientists (MLS) worklist, prompting a required phone call notification. In this study, a pre- and post-implementation analysis was conducted, comparing critical value communication metrics over a 6-month period following implementation go-live with the prior phone-based workflow. Outcomes measured included the number of successful closed loop completions, estimated MLS time savings, and the median time to communication closure with nursing. Extensive nursing training was conducted prior to implementation to support a successful transition. Results A total of 26,840 inpatient critical laboratory values were analyzed during the 6-month post-implementation period. Closed loop electronic completion was achieved for 19,004 results (71%), eliminating phone calls for these cases. The remaining 7,783 (29%) required a direct phone call due to lack of acknowledgment within 10 minutes. Eliminating 19,004 manual phone calls resulted in an estimated 57,012 minutes (>950 hours) of MLS time saved over 6 months, allowing strategic redeployment of resources to higher value laboratory activities. The median time to electronic acknowledgment was 47 seconds, compared with a pre-implementation median communication time of 5 minutes using phone calls, demonstrating a significant decrease in communication time and enabling faster patient intervention. No increase in missed or delayed critical result notifications was identified following implementation. Immediate high-performance post go-live reflected the effectiveness of pre-implementation structured project management, workflow analysis, and extensive education. Conclusion The implementation of the EMR integrated closed loop communication system significantly improved the efficiency, timeliness, and standardization of inpatient critical value notification at TGH while reducing manual laboratory workload. This laboratory driven workflow redesign represents a scalable, sustainable quality improvement model that strengthens critical value communication and supports high-reliability patient care. Next step includes expanding closed loop communication to physicians following implementation of Epic First Contact at our institution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-262 Push, Chat, Loop Me In: Evaluating the Performance of a Tiered Closed-Loop Critical Result Notification SystemClinical Chemistry · 2026
- Critical result thresholds and notification practices in clinical laboratories.Critical reviews in clinical laboratory sciences · 2026
- B-103 Implementation of an Automated Critical Value Module in a Latin American Oncology Institute Laboratory: Process Optimization and Clinical Impact AnalysisClinical Chemistry · 2026
- Distribution and Hospital Information System Acknowledgment Timeliness of Critical Value Reports in a Large Tertiary Hospital: A Retrospective Descriptive Study.Journal of nursing management · 2026
- Electronic Patient‐Reported Health‐Related Quality of Life Trajectories in ICU Survivors: A Multicentre Pilot Study‐Within‐a‐Trial ProtocolActa Anaesthesiologica Scandinavica · 2026
- Improving Cuff Leak Test Documentation: A Single Center Quality Improvement Project.Respiratory care · 2026