B-220 Detection of myasthenia gravis autoantibodies using an innovative cell-based immunofluorescence assay
Jackie Weiss, Dominik Jäger, Francesca Andreetta, Ornella Simoncini, Renato Mantegazza, Luise Zech, Rose Kohlie, Ario Mirian,
Key points
From the paper's conclusion- Here we studied trueness and diagnostic performance of the Myasthenia Gravis Mosaic 2 IIFT (indirect immunofluorescence test, Euroimmun), a newly developed CBA based on transfected human cell lines separately expressing the corresponding target antigens AChR and MuSK for parallel detection of IgG autoantibodies against adult acetylcholine receptor (AChR-E), fetal acetylcholine receptor (AChR-G), a
Abstract
Background Myasthenia gravis (MG) is an immune-mediated neuromuscular junction disorder and one of the most prevalent neurological autoimmune diseases. Serological markers of MG are autoantibodies against nicotinic acetylcholine receptors (AChR) and autoantibodies against muscle-specific kinase (MuSK). Autoantibodies against AChR and MuSK are detected in approximately 80% and 3% of MG patients, respectively, while 15% of MG cases are seronegative [1,2]. The current gold standard for the detection of anti-AChR and anti-MuSK autoantibodies is radioimmunoprecipitation assay (RIA), despite its disadvantage of requiring radioactive reagents. An innovative technology for the detection of autoantibodies is the cell-based indirect immunofluorescence assay (CBA). Here we studied trueness and diagnostic performance of the Myasthenia Gravis Mosaic 2 IIFT (indirect immunofluorescence test, Euroimmun), a newly developed CBA based on transfected human cell lines separately expressing the corresponding target antigens AChR and MuSK for parallel detection of IgG autoantibodies against adult acetylcholine receptor (AChR-E), fetal acetylcholine receptor (AChR-G), and MuSK. Methods The trueness was determined by measuring samples with analyte concentrations covering the relevant measurement range of the CBA, i.e. 150 serum samples from MG patients (50 anti-AChR positive, 50 anti-MuSK positive, 50 anti-AChR and anti-MuSK negative), with the CBA and RIAs serving as the reference test system. To determine the CBA’s clinical sensitivity, 395 serum samples from MG patients (144 ocular MG, 251 generalised MG) were analysed. The clinical specificity was determined by analysing 323 serum samples from patients with diagnoses relevant for MG differential diagnostics (223 patients without a neuromuscular disorder, 20 rheumatoid arthritis, 20 systemic lupus erythematosus, 20 Hashimoto’s thyroiditis, 20 myositis, and 20 multiple sclerosis patients). Results The Myasthenia Gravis Mosaic 2 IIFT had a positive agreement of 96% and a negative agreement of 100% with an Anti-AChR RIA as well as a positive agreement of 98% and a negative agreement of 100% with an Anti-MuSK RIA. The detection of anti-AChR autoantibodies resulted in a clinical sensitivity of 76.7% and a clinical specificity of 99.4%, while testing for anti-MuSK autoantibodies resulted in a specificity of 100%. The sensitivity for detection of anti-MuSK autoantibodies was 2.8% in the MG patient cohort (N=395), but 39.3% in 28 anti-AChR-negative samples (cases of generalized MG). Conclusion The Myasthenia Gravis Mosaic 2 IIFT (Euroimmun) had excellent agreement with reference RIAs. Due to its high diagnostic sensitivity and specificity, the CBA has gold standard potential as a first-line test for MG serology. The CE-IVDR marked CBA is easy to implement in the laboratory routine; its processing can be either manually or fully automatically with faster incubations compared to ELISA or RIA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A primary human muscle cell-based assay for detecting myasthenia gravis autoantibody binding and assessing AChR cluster impairmentbioRxiv · 2026
- Diagnostic Performance of Three Serological Assays in Myasthenia Gravis: A Prospective Multicentre StudyScandinavian Journal of Immunology · 2025
- From seropositivity to pathogenicity: causal evidence for autoantibodies in myasthenia gravis.Frontiers in immunology · 2026
- IgA autoantibodies demonstrate a novel mechanism of MuSK myasthenia gravis pathologyBrain · 2025
- MuSK myasthenia gravis: from antigen-antibody to clinical translation.Frontiers in immunology · 2026
- Relative frequencies of muscle specific kinase antibody myasthenia in 46 centres worldwideBrain · 2026