Clinical Chemistry

B-167 Combined Plasma H3.1 Nucleosomes with Creatinine and Lactate for Early Sepsis Detection in Emergency Department Patients

Terry Kelly, Aristotelis Kotronoulas, Andrew Retter, M I tchell Aicher, Marielle Herzog, Tom Soriano

Observational · n=193

Key points

From the paper's conclusion
  • We hypothesized that integrating plasma H3.1 nucleosomes with routine chemistry markers could improve early identification of sepsis at ED presentation.

Abstract

Background Early recognition of sepsis in the emergency department (ED) remains challenging, and existing clinical scores and routine biomarkers have limited sensitivity. Circulating nucleosomes containing histone H3.1 are biomarkers of cellular injury and organ dysfunction. We hypothesized that integrating plasma H3.1 nucleosomes with routine chemistry markers could improve early identification of sepsis at ED presentation. Methods We performed a retrospective analysis of 193 unselected adult ED patients. Plasma H3.1 nucleosome concentrations were measured at presentation using a chemiluminescent immunoassay, alongside routine creatinine and lactate testing. Sepsis diagnosis was adjudicated retrospectively by two senior clinicians according to Sepsis-3 criteria. A multivariable logistic regression model incorporating log-transformed H3.1, creatinine, and lactate was developed to discriminate sepsis from non-sepsis. Model performance was assessed by area under the receiver operating characteristic curve (AUC) with internal cross-validation. Sensitivity and specificity were calculated at the optimal Youden’s J threshold. Results Of 193 patients, 94 (49%) met Sepsis-3 criteria. The combined H3.1–creatinine–lactate model demonstrated strong discrimination with a cross-validated AUC of 0.863 (95% CI, 0.823–0.902). At the Youden-optimal threshold, sensitivity was 89.7% and specificity was 78.8%, enabling identification of the majority of sepsis cases while avoiding nearly four-fifths of false-positive classifications. The addition of H3.1 provided incremental diagnostic value beyond routine markers alone. Conclusions A logistic regression model integrating plasma H3.1 nucleosomes with creatinine and lactate achieved high early diagnostic accuracy for sepsis in a general ED population. This approach requires addition of only a single novel biomarker to existing laboratory workflows and may provide actionable diagnostic support at the frontline. Prospective multicenter validation is warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers