B-167 Combined Plasma H3.1 Nucleosomes with Creatinine and Lactate for Early Sepsis Detection in Emergency Department Patients
Terry Kelly, Aristotelis Kotronoulas, Andrew Retter, M I tchell Aicher, Marielle Herzog, Tom Soriano
Key points
From the paper's conclusion- We hypothesized that integrating plasma H3.1 nucleosomes with routine chemistry markers could improve early identification of sepsis at ED presentation.
Abstract
Background Early recognition of sepsis in the emergency department (ED) remains challenging, and existing clinical scores and routine biomarkers have limited sensitivity. Circulating nucleosomes containing histone H3.1 are biomarkers of cellular injury and organ dysfunction. We hypothesized that integrating plasma H3.1 nucleosomes with routine chemistry markers could improve early identification of sepsis at ED presentation. Methods We performed a retrospective analysis of 193 unselected adult ED patients. Plasma H3.1 nucleosome concentrations were measured at presentation using a chemiluminescent immunoassay, alongside routine creatinine and lactate testing. Sepsis diagnosis was adjudicated retrospectively by two senior clinicians according to Sepsis-3 criteria. A multivariable logistic regression model incorporating log-transformed H3.1, creatinine, and lactate was developed to discriminate sepsis from non-sepsis. Model performance was assessed by area under the receiver operating characteristic curve (AUC) with internal cross-validation. Sensitivity and specificity were calculated at the optimal Youden’s J threshold. Results Of 193 patients, 94 (49%) met Sepsis-3 criteria. The combined H3.1–creatinine–lactate model demonstrated strong discrimination with a cross-validated AUC of 0.863 (95% CI, 0.823–0.902). At the Youden-optimal threshold, sensitivity was 89.7% and specificity was 78.8%, enabling identification of the majority of sepsis cases while avoiding nearly four-fifths of false-positive classifications. The addition of H3.1 provided incremental diagnostic value beyond routine markers alone. Conclusions A logistic regression model integrating plasma H3.1 nucleosomes with creatinine and lactate achieved high early diagnostic accuracy for sepsis in a general ED population. This approach requires addition of only a single novel biomarker to existing laboratory workflows and may provide actionable diagnostic support at the frontline. Prospective multicenter validation is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early plasma cell-free DNA and monocyte human leukocyte antigen-DR expression for predicting 28-day mortality in sepsis: A single-center prospective cohort study with internal validation.The Journal of international medical research · 2026
- B-147 Biomarker NMI: early Warning, Differential Diagnosis, and Treatment Monitoring in SepsisClinical Chemistry · 2026
- A composite inflammatory-renal prognostic score predicts in-hospital mortality in older adults with sepsis.Mechanisms of ageing and development · 2026
- Diagnostic and prognostic value of neutrophil extracellular traps in sepsis and their correlation with inflammatory factorsBMC Infectious Diseases · 2026
- Predictive Role of Neutrophil-to-Lymphocyte Ratio and Serum Creatinine in the Early Detection of Sepsis-Related Organ Dysfunction.Cureus · 2026
- Development and validation of a nutrition-integrated nomogram for predicting 28-day mortality in sepsis patientsFrontiers in Nutrition · 2026