B-150 Impact of High-Sensitivity CLIA Technology on Prenatal TORCH Screening: A Study of 810 Public Healthcare Cases
Claudia Cruz, Paola Santos, Addy Helguera, Oscar Villavicencio, Sharon Ochoa, Andrea Moreno, Jeannette Navarrete, Paola Lasso
Key points
From the paper's conclusion- These findings emphasize that the clinical laboratory must lead the integration of serological results with confirmatory tools—such as IgG avidity and molecular diagnostics—to optimize prenatal management, reduce patient anxiety, and prevent unnecessary medical interventions.
Abstract
Background TORCH group infections (T. gondii, Rubella, CMV, and HSV) are significant drivers of maternal-fetal morbidity. A major challenge in clinical diagnostics is the interpretation of IgM markers, which can persist for over a year or show non-specific reactivity. This study aimed to evaluate the seroprevalence of these infections in a public healthcare setting in Bogotá, Colombia, focusing on the laboratory's ability to differentiate acute from non-recent infections to guide clinical decision-making. Methods A cohort of 810 pregnant women across all three trimesters was evaluated at the Subred Integrada de Servicios de Salud Sur E.S.E. Serological testing for IgG and IgM was performed using high-sensitivity Chemiluminescence Immunoassays (CLIA) on the Mindray CL-Series platform. The study design also integrated real-time PCR (q-PCR) protocols for pathogen DNA detection (e.g., 529 bp fragment for T. gondii) in cord blood to investigate vertical transmission in suspicious cases. Results The prevalence of reactive IgM was notably low, and in the vast majority of cases, it was accompanied by positive IgG, indicating non-recent infections: T. gondii: 1.6% (n=13) were IgM+; 92% of these also tested IgG+, suggesting IgM persistence. CMV: 1.23% (n=10) showed reactive IgM, all of which had concomitant positive IgG (non-primary infection). HSV-1/2: Showed the highest reactivity at 3.7% (n=30) for IgM; 93% were also IgG positive. Rubella: 0.86% (n=7) were IgM+, predominantly showing profiles of previous immunity. Conclusion High-sensitivity CLIA technology provides superior antibody stratification, revealing that IgM positivity in this population frequently represents persistence or past infections rather than acute risks. These findings emphasize that the clinical laboratory must lead the integration of serological results with confirmatory tools—such as IgG avidity and molecular diagnostics—to optimize prenatal management, reduce patient anxiety, and prevent unnecessary medical interventions. Acknowledgments: The authors would like to thank Mindray Medical for their support and contribution to this research, providing the advanced technology and diagnostic solutions necessary to achieve these results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and analytical validation of a multiplex qPCR assay for Toxoplasma gondii , Treponema pallidum , cytomegalovirus, and herpes simplex virus types 1 and 2 in neonatesPeerJ · 2026
- Universal Cytomegalovirus Screening in the First Trimester of Pregnancy: The Multicentre Observational Cohort Study in the Area of Barcelona ( CITEMB Study)BJOG An International Journal of Obstetrics & Gynaecology · 2026
- Seroprevalence of toxoplasmosis, rubella, cytomegalovirus, herpes simplex, and syphilis infections among pregnant women and infants in Malaysia: a systematic review and meta-analysis.PeerJ · 2026
- Using dried blood spots to estimate Toxoplasma gondii seroprevalence in pregnant women in Catalonia, Spain, and to serologically diagnose congenital toxoplasmosisPLoS neglected tropical diseases · 2026
- Situación actual del cribado prenatal de la toxoplasmosis en EspañaBoletín epidemiológico semanal: Vigilancia epidemiológica · 2026
- Urine as a Noninvasive Diagnostic Approach for Toxoplasma gondii: A Systematic Review of Molecular and Serological Detection Methods.Journal of parasitology research · 2026