B-143 Incorporation of Recombinant Antibodies in Quality Measurement Tools as a Robust Replacement for Natively Occurring Antibodies

Daniel Avery, Jessica Pawlak, Holger Hannemann

Key points

From the paper's conclusion
  • Implementation of recombinant antibodies reduces reliance on native human sourced plasma while improving supply chain, increasing lot-to-lot consistency, and allowing for consolidation of analytes into multi-analyte QMTs.

Abstract

Background Automated serology assays are widely used in centralized clinical laboratories and require quality measurement tools (QMTs) to be diagnostically relevant. QMTs are generally manufactured using native human plasma. However, plasma carries various antibody backgrounds depending on the mix of pathogens an individual has been exposed to at the time of collection, and collection of plasma at the appropriate specific IgM or IgG levels and absence of other potentially interfering analytes is difficult due to (1) the plasma collection window; (2) co-infections or multivalent vaccinations; (3) rarity of infection. In addition, these factors increase the difficulty in identifying true negative plasma. To stabilize supply of QMTs, the use of recombinant human IgM and IgG antibodies and antibody depletion of plasma for QMT manufacture is shown in this study. Methods Recombinant antibodies were produced as IgM or IgG antibodies in HEK293 cells, subsequently purified and evaluated on IVD testing platforms. Human plasma was chromatographically cleared of native antibodies, and the absence of antibodies was verified through testing in triplicate on Roche cobas Pro & Pure and Abbott ARCHITECT & Alinity platforms. The resulting negative plasma was used for evaluation of recombinant antibody recognition by serology assays using recombinant anti-Rubella IgM, Toxoplasma IgM and HBc IgM spiked into processed plasma at 20ug/mL and 10ug/mL, with Rubella and Toxoplasma samples tested on the Roche Pure platform and HBc IgM samples on the Abbott Alinity platform to evaluate recoveries. Results The processed plasma tested negative for all applicable serology markers on the Abbott and Roche platforms. Rubella IgM recovery was 75 COI at a 20 ug/mL on the Roche cobas Pure Rubella IgM assay. Toxoplasma IgM recovered 2.5 COI at a 20 ug/mL on the Roche cobas Pure Toxoplasma IgM assay and HBc IgM recovered 3 S/CO at a 10ug/mL on the Abbott ARCHTITECT and Alinity HBc IgM assays. All three recombinants were positive for assay recognition, diluted linearly, and can be used in place of high titer samples. Conclusion Removal of inherent IgG and IgM antibodies in human sourced plasma allows for a consistent patient-like matrix for use in QMTs. Since serology assays are based on antigen: antibody avidity, the native polyclonal antibody response found in patient plasma can be variable, leading to inconsistent QMT manufacturing. The use of recombinant antibodies in QMTs requires the identification and development of specific antibodies that are compatible with serological assays. As IVDR requirements are updated to ensure device claims on performance, safety and traceability, the use of recombinant materials ensures a reliable means to satisfy the parameters outlined for IVD devices, including controls, is met and maintained. Implementation of recombinant antibodies reduces reliance on native human sourced plasma while improving supply chain, increasing lot-to-lot consistency, and allowing for consolidation of analytes into multi-analyte QMTs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers