B-133 Analytical performance of a soluble B-cell maturation antigen ELISA assay for Research Use Only
Robert van Heezik, Charlotte Crawford, Jenna Bailey, Jamie-Leigh Logan, David Edwards, Ayesha Mulla, Eve Roy, Waqar Hussain
Key points
From the paper's conclusion- Here we describe the analytical evaluation of a research use only sBCMA ELISA assay, in development by The Binding Site (part of ThermoFisher Scientific).
Abstract
Background Soluble B-cell maturation antigen (sBCMA) is a novel marker for B-cell and plasma dyscrasias. sBCMA levels have been shown to predict clinical outcomes and associated treatment response in multiple myeloma patients, garnering considerable research interest. sBCMA levels are also elevated in monoclonal gammopathies; SMM, MGUS, WM, as well as in CLL, MS. sBCMA is suppressed in immunodeficiencies, such as PID, CVID, XLA, and PAD. Here we describe the analytical evaluation of a research use only sBCMA ELISA assay, in development by The Binding Site (part of ThermoFisher Scientific). The assay employs a six-point calibration curve, with a standard measuring range of 3 – 100 ng/mL and sensitivity of 3 ng/mL using a 1/25 sample dilution. Samples exceeding the standard measuring range are re-measured at a dilution of 1/250, with an upper limit of 1000 ng/mL. Calibration is standardized through traceability to an internal reference standard produced from a recombinant BCMA-HSA fusion protein, with assigned sBCMA concentration quantified by amino acid analysis performed at a UKAS accredited laboratory to ISO/IEC 17025:2017 standard. All reagents are provided in a ready-to-use liquid stable format, with only the wash buffer requiring a dilution to working concentration. The assay employs a 96-well break apart ELISA plate pre-coated with polyclonal anti-human sBCMA antibodies. It has turnaround time of less than 3 h, comprising 2.5 h of incubation and required wash steps. Methods Serum samples from 81 apparently healthy donors were analysed to determine the sBCMA concentration. Analytical precision was assessed using five serum samples at a range of BCMA concentrations tested in duplicate on four plates per day, repeated on 10 days (n=80 results per sample). Linearity was evaluated using samples that extended >±10% beyond the upper and lower limits of the standard assay measuring range. Limit of quantitation (LoQ) was assessed at 2.55ng/mL by testing 5 replicates of 4 samples on 3 days. Interference was assessed at two serum concentrations challenging with 10 g/L haemoglobin, 40 mg/dL conjugated bilirubin, 40 mg/dL unconjugated bilirubin, 1500 mg/dL triglyceride and 2000 mg/dL intralipid. Physiological ligands associated with sBCMA were also evaluated in interference testing; 200 ng/mL APRIL and 35 ng/mL BAFF. Results A 95% cutoff was applied to the 81 serum samples from apparently healthy donors, producing a sBCMA concentrations range of 4.65 - 23.04 ng/mL range. In the analytical precision study, all samples reported <9.2% within run CV, <7.2% between-run CV, <6.5% between-day CV, and <13.4% total CV. Linearity was demonstrated at 2.13 ng/mL – 144.75 ng/mL with <10% non-linearity down to 24.03 ng/mL; after which <2.4 ng/mL absolute non-linearity. For the limit of quantitation study, all samples reported <12.2% total CV. All samples spiked with the interfering substances reported <±10% difference when compared to equivalent negative controls. Conclusion This sBCMA ELISA assay provided a reliable and precise method for quantifying sBCMA in human serum, in a non-clinical setting. Accuracy of reported concentrations was ensured by traceability to an internal reference standard quantified by amino acid analysis at a UKAS accredited laboratory to ISO/IEC 17025:2017 standard.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Imaging B cell maturation antigen in multiple myeloma.The Journal of clinical investigation · 2026
- Soluble BCMA Defines Spatial Phenotypes and Prognosis in Newly Diagnosed Multiple Myeloma.Blood · 2026
- Evaluation of a multiple myeloma synthetic cell mimic as an assay control for flow cytometry.Cytometry. Part B, Clinical cytometry · 2026
- Dynamics of BCMA expression in patients with relapsed/refractory multiple myeloma receiving BCMA-directed CAR-T therapyBlood Cancer Journal · 2026
- B-cell maturation antigen targeted PET/CT imaging in multiple myeloma: a first-in-human studyJournal of Hematology & Oncology · 2025
- Development and Preclinical Evaluation of 68Ga-Labeled BCMA-Targeting Nanobodies for PET Imaging of Multiple Myeloma.Journal of medicinal chemistry · 2026