B-104 Reducing Preventable Internal Laboratory Recalls in a Specialized Oncology Center: A Quality Improvement Initiative

Laura Noro, Ximena Varela

Observational

Key points

From the paper's conclusion
  • Conclusion In a specialized oncology center where laboratory results directly impact therapeutic decisions, nearly all preventable recall events originated from two modifiable domains: preanalytical sample collection and administrative order entry processes.

Abstract

Background In oncology care, laboratory results directly influence critical clinical decisions, including chemotherapy administration, radiotherapy scheduling, transfusions, and invasive procedures. Delays or repeat visits due to preventable laboratory errors can negatively affect treatment timelines, patient safety, and emotional well-being. Patient recall after an initial laboratory visit increases operational burden and disrupts continuity of care. While some recalls are patient-related or clinically justified, internal process failures represent preventable quality gaps. In a high-complexity oncology center, minimizing such failures is essential to maintain timely, safe, and patient-centered care. Methods A retrospective analysis of all patient recall events recorded during 2025 was conducted in the clinical laboratory at the Instituto Alexander Fleming, a specialized oncology center in Argentina serving exclusively cancer patients. Events were categorized by responsible party and detailed cause. Patient-related causes and clinically justified validation discrepancies were excluded to focus exclusively on preventable internal process failures. Pareto analysis was applied to identify priority areas for targeted quality improvement. Results A total of 553 recall events were identified. After excluding patient-related events (427 cases, 77.2%) and clinically justified validation discrepancies (50 cases), 76 preventable internal recall events remained for analysis. Among these internal events: Laboratory technician: 40 cases (52.6%), administrative staff: 34 cases (44.7%), physician: 2 cases (2.6%) The predominant failure modes included preanalytical sampling errors (hemolysis, coagulation, insufficient volume), failure to collect required specimens, omission of test entry in the laboratory information system, and lack of health insurance authorization for laboratory tests. Pareto analysis demonstrated that preanalytical and administrative failures accounted for more than 95% of preventable internal recall events. Conclusion In a specialized oncology center where laboratory results directly impact therapeutic decisions, nearly all preventable recall events originated from two modifiable domains: preanalytical sample collection and administrative order entry processes. Targeted quality improvement strategies should include reinforcement of standardized collection protocols, structured order verification workflows, and continuous training of staff. Additionally, strengthening and clearly reinforcing patient instructions—particularly when preparation requirements are involved—may further reduce avoidable recalls and improve coordination between laboratory processes and patient readiness. These interventions have the potential to protect treatment timelines, reduce operational inefficiencies, and enhance patient-centered oncology care.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers