Clinical Chemistry

B-085 In-house validation of Homologous Recombination Deficiency (HRD) testing by Whole Exome Sequencing in a cohort of cancer patients at Dartmouth Hitchcock Medical Center (DHMC)

Debopriya Chakraborty

Observational · n=40

Key points

From the paper's conclusion
  • We proceeded with the remaining 40 samples and 3 controls for our validation study.

Abstract

Background Homologous Recombination Deficiency (HRD) is defined by inability of tumor cells to repair DNA double-stranded breaks by the HR Repair (HRR) pathway, resulting in genomic instability. It is associated with somatic and germline pathogenic mutations in HRR pathway genes and “genomic scars”, which are structural variations often measured by quantifying loss of heterozygosity (LOH), large scale transitions (LSTs) or chromosomal breaks between adjacent regions, and telomeric allelic imbalances (TAI). Current challenges in HRD testing involves lack of consensus in HRD classification across different assays, tumor purity, and heterogeneity within and among tumor types. Addressing these concerns could guide HRD-biomarker driven poly (ADP-Ribose) polymerase inhibitor (PARPi) therapy in a wide range of cancer patients. Here, we evaluate the performance of HRD assessment on our in-house whole exome sequencing (WES) assay. Methods Tumor genomic DNA was extracted from 47 formalin-fixed, paraffin-embedded (FFPE) gynecologic cancer tissue samples using the Purigen system. DNA was quantified using Qubit HS and WES was performed on an Illumina NovaSeq sequencer. All samples had been previously tested for HRD at Myriad Genetics (46) (Myriad MyChoice®) / Foundation Medicine (1) (FoundationOne®) reference laboratories. HRD scores were determined for these samples, along with three Seraseq® controls (High-positive, low-positive and negative) using the HRD-caller in AUGMET, our in-house bioinformatics pipeline. We determined HRD status as follows: HRD Score = Score [LOH+ LST + TAI]. Test Performance Assessment was measured as: Positive Percent Agreement % (PPA %) = TP/ TP + FN Accuracy % = TP + TN/ TP+ TN + FP + FN (TP: True Positive, TN: True Negative, FP: False Positive, FN: False Negative) Results Of the 47 patient samples, 17 samples originated from DHMC and 30 from University of Vermont (UVM). Seven of these had insufficient DNA quantity and were excluded from HRD analysis. We proceeded with the remaining 40 samples and 3 controls for our validation study. We set our cut-off at 45; 21 samples including the controls were called HRD-positive/deficient (score >=45), and 22 HRD-negative/proficient (score <45). Seven cases were discordant, likely due to low tumor content (<20%) in one sample that was excluded from final analysis, or due to inter-assay variability. The PPA of our assay was 81.81%, with 85.71% accuracy when compared to the results from the reference laboratories for HRD status determination. Conclusions Our HRD results showed overall good concordance with the FDA-approved HRD test results although some discrepancy was seen. This can be attributed to variability in HRD calling algorithms and the genomic changes included in HRD scores, as well as lack of availability of a gold standard for HRD testing. Due to highly complex nature of HRD biology involving multiple genomic events, the variabilities in HRD classification techniques are inevitable. Despite these challenges, developing standard methods for scoring and detection of HRD that could predict therapeutic response in patients would be immensely beneficial.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers