Clinical Chemistry

B-074 Suspicion of Blastic Plasmacytoid Dendritic Cell Neoplasm (BPDCN) Through Mindray BC-6800Plus Scattergram Abnormalities in a Young Adult with Down Syndrome

Ricardo Rodriguez, Nancy Herrera, Roberto Vilca

Case report

Key points

From the paper's conclusion
  • Mindray BC-6800Plus hematology analyzer identified an atypical cell population with very specific fluorescence characteristics and an unusual distribution.

Abstract

Background National Institute of Neoplastic Diseases (INEN) is a reference center for diagnosis and specialized treatment of cancer in Peru. The number of cases treated each year is increasing, with hematological neoplasms accounting for a significant proportion of patients evaluated at Hematology Lab. Automated blood counts are currently used alongside morphological analysis for the initial detection of abnormal cell populations. Blastic plasmacytoid dendritic cells neoplasm (BDPCN) is a rare entity characterized by proliferation of blast cells derived from plasmacytoid dendritic cell precursors. It can present with bone marrow involvement and a leukemic phase, clinically mimicking acute leukemia. Due to its morphological overlap with other myeloid neoplasms, its timely recognition requires the integration of CBC and smear findings together with immunophenotyping. Accurate identification allows for an appropriate differential diagnosis to be established in relation to acute myeloid leukemias. Methods A 24-year-old male with Down syndrome referred from another institution with presumptive diagnosis of acute myeloid leukemia. Upon admission, he presented with marked pallor and conjunctival bleeding. A CBC was performed using Mindray BC-6800Plus hematology analyzer, and cell population data (CPD) and two-dimensional scattergrams in leukocyte differential channel (DIFF) were evaluated. Al smear microscopic review was performed with differential counting, and automated findings were correlated with the observed cell morphology. Results CBC showed RBC 2.82 ×10¹²/L; HGB 101 g/L; HCT 30.5%; VCM 108.2 fL; HCM 35.8 pg; CHCM 331 g/L; PLT 117 ×10?/L; WBC 6.60 ×10?/L. Leukocyte scattergram (DIFF channel) showed an abnormal cluster displaced between lymphocyte and monocyte regions, and above them towards areas of high fluorescence intensity. Neutrophils showed variable internal complexity, which did not correspond to typical distribution. The graph was suggestive of an immature/ malignant suspected. Cells with blast morphology were found in smears. The immunophenotype study identified an immature population that was positive for CD45+, CD4+, CD123+, HLA-DR+ and negative for other myeloid and lymphoid markers, consistent with BDPCN. Conclusion This case highlights the diagnostic value of CPD and scattergram interpretation to trigger early smear review and flow cytometry referral, particularly in rare hematologic neoplasms. Mindray BC-6800Plus hematology analyzer identified an atypical cell population with very specific fluorescence characteristics and an unusual distribution. Integration of quantitative data and graphical interpretation was key to early suspicion of blast proliferation and subsequent diagnosis by flow cytometry. Comprehensive analysis of hematological parameters, cell population data (CPD), and triggered prompt smear review are essential for hematological neoplasms diagnosis. In rare entities, timely identification through a suggestive graph from the analyzer contributed to better guidance in medical decision-making.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers