Clinical Chemistry

B-071 Optimizing G6PD Screening Workflow to Enable Safe TLS Management in Pediatric Oncology: A Reflex Testing Implementation Study

Nazmin Bithi

Key points

From the paper's conclusion
  • Conclusion This project demonstrates the feasibility and clinical utility of implementing a rapid G6PD screening and reflex testing pathway in a high-volume pediatric oncology setting.

Abstract

Background Glucose-6-phosphate dehydrogenase deficiency (G6PDD) is a globally prevalent red cell enzyme disorder that carries clinical significance in pediatric oncology. Medications such as rasburicase and trimethoprim-sulfamethoxazole, frequently used during tumor lysis syndrome (TLS) management and infection prophylaxis, can cause oxidative stress and severe hemolysis in G6PDD patients. Prior to this quality improvement initiative, our institution relied solely on send-out quantitative G6PD testing with result delays of several days—posing challenges in timely decision-making during acute TLS scenarios. To implement a rapid, in-house qualitative G6PD screening strategy with reflex quantitative confirmation for abnormal results, enabling faster risk stratification and medication guidance in high-risk pediatric oncology patients. Methods A laboratory-clinical collaboration enabled validation and go-live of a qualitative G6PD assay in our pathology lab. Results interpreted as “Intermediate” or “Deficient” reflexed automatically to quantitative testing at a reference facility. Screening was integrated into our tumor lysis protocol and embedded into a customized Epic orderset. We tracked test volumes, turnaround time (TAT), and concordance between qualitative and quantitative results using a reference range of 9.7–16.9 U/g Hb. Results Among the 74 patients screened, 42 underwent reflex quantitative testing due to abnormal qualitative results. Of these, all 6 patients identified as “Deficient” by qualitative screening were confirmed by quantitative testing. Importantly, of the 33 patients initially classified as “Intermediate,” 13 (39%) were quantitatively confirmed as deficient—indicating that a substantial number of G6PD-deficient patients could be missed if reflex testing were not performed. The remaining 20 “Intermediate” patients were quantitatively normal. The average TAT for the qualitative assay remained below 6 hours, meeting our operational target and allowing for timely therapeutic decisions. Conclusion This project demonstrates the feasibility and clinical utility of implementing a rapid G6PD screening and reflex testing pathway in a high-volume pediatric oncology setting. By identifying patients at risk for hemolytic complications prior to rasburicase exposure, we enhanced patient safety while improving turnaround times. These findings underscore the need for reflex testing in intermediate cases and support broader adoption of integrated screening workflows in institutions managing TLS.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

B-071 Optimizing G6PD Screening Workflow to Enable Safe TLS Management in Pediatric Oncology: A Reflex Testing Implementation Study — Science Skim